EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya


Kampus ITS Sukolilo - Surabaya 60111

Phone : 031-5921733 , 5923623
Fax : 031-5937774
E-mail : libits@its.ac.id
Website : http://library.its.ac.id

Support (Customer Service) :
timit_perpus@its.ac.id




Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Moh. Fandika Aqsa


Davi Wahyuni


Tondo Indra Nyata


Anis Wulandari


Ansi Aflacha




ITS » Master Theses » Teknik Struktur S2
Posted by dee@its.ac.id at 02/12/2014 19:30:54  •  1119 Views


STUDI PERILAKU DINDING GESER PELAT BAJA STEEL PLATE SHEAR WALL TERHADAP KONFIGURASI PENGAKU LATERAL

STUDY BEHAVIOR STEEL PLATE SHEAR WALLS OF CONFIGURATION LATERAL STRIFFENERS

Author :
NUSSA, RAMDAN TAUFIQ ( 3110202003 )




ABSTRAK

Akhir-akhir ini telah dikembangkan suatu sistem yang dapat mereduksi gaya gempa untuk struktur gedung baja yaitu Dinding Geser Pelat Baja atau Steel Plate Shear Wall SPSW. Dinding geser pelat baja adalah sebuah sistem penahan beban lateral yang terdiri dari pelat baja vertical berdinding tipis menghubungkan balok dan kolom disekitarnya dan terpasang dalam satu atau lebih pelat sepanjang ketinggian struktur membentuk sebuah dinding penopang. Perilaku dari dinding geser pelat baja ini masih belum bisa diprediksi oleh karena itu sampai dengan saat ini sistem SPSW masih dalam tahap penelitian laboratorium walaupun sudah ada beberapa gedung yang menggunakan sistem ini contohnya gedung Hospital di California Baldeli 1983. Sampai dengan saat ini belum ada suatu peraturan code yang mengatur sistem ini. Adapun tujuan yang ingin dicapai adalah 1.Menghitung respon inelastik drift antar tingkat gaya geser dasar simpangan atap suatu bangunan dengan menggunakan steel plate shear wall. 2.Mengetahui perilaku elemen Steel Plate Shear Wall SPSW apabila diberi pengaku lateral tambahan atau konfigurasi pengaku lateral tambahan. 3.Mengetahui permodelan SPSW dengan perhitungan analitis. 4.Mengetahui permodelan sistem SPSW pada sturktur gedung dengan Finite Element Software.Dalam studi ini terdapat 9 permodelan dimana setiap model memiliki ketebelan pelat dan sistim bracing yang berbeda-beda. Kesimpulan yang dapat diambil dari studi ini adalah Perilaku elemen steel plate shear wall SPSW terhadap ketebalan pelat baja menunjukan bahwa model yang menggunakan tebal pelat yang paling tebal Model AT10 BT10 dan CT10 mengalami perpindahan yang paling kecil jika dibandingkan dengan model menggunkan pelat tipis Model AT3 BT3 dan CT10. Perbandingan antara SPSW tanpa pengaku dan SPSW yang diberi pengaku menunjukan bahwa pengaku lateral berperan penting dalam menahan gaya lateral beban dorong ini ditunjukan dengan perpindahan dan tegangan yang terjadi pada Model SPSW yang berpengaku lebih kecil 40 jika dibanding dengan yang tidak berpengaku dan setelah dilakukan validasi dengan menggunakan hand method maka dapat ditarik kesimpulan bahwa hasil dari finite element software dengan hasil dengan cara analitis Hand Methode menunjukan hasil yang sama.


ABSTRACT

Lately it has developed a system that can reduce earthquake forces for structural steel buildings that Steel Plate Shear Wall SPSW. Steel plate shear wall is a lateral load restraint system that consists of vertical thin-walled steel plate connecting beams and columns around it and installed in one or more plates along the height of the structure to form a buttress. The behavior of steel plate shear wall is still not predictable therefore until now SPSW system is still in its research laboratories although there are some buildings that use this system for example buildings Hospital in California Baldeli 1983. Up to now there is no one rule code that regulate these systems. The goals to be achieved are 1. Calculate inelastic response drift between levels the base shear force a roof deviation of a building using a steel plate shear wall. 2. Knowing the behavior of elements of Steel Plate Shear Wall SPSW when given additional lateral bracing or additional lateral bracing configuration. 3. Knowing the SPSW modeling with analytical calculations. 4. Knowing the SPSW modeling system in its structure building with ABAQUS software. In this study the modeling 9 wherein each model has a thickness of plate and bracing system that is different. The conclusion that can be drawn from this study behavior the spsw element to indicate that the thickness of steel plate modeling using the thickest slab thickness suffered most displacement is small in comparison with modeling using thin plate. Comparison between spsw without stiffeners and stiffeners spsw given shows that the stiffeners spsw is the most optimal as shown by the smaller displacement.



KeywordsSteel Plate Shear Wall (SPSW); Finite Element Software; Lateral Stiffness
 
Subject:  Konstruksi dinding baja
Contributor
  1. Budi Suswanto, ST., MT., Ph.D
  2. DR. Ir. Hidayat Soegihardjo, MS
Date Create: 16/01/2014
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Master-31103140001006
Collection ID: 31103140001006
Call Number: RTS 624.176 Nus s


Source
Master Thesis of Civil Engineering, RTS 624.176 Nus s, 2014

Coverage
ITS Community

Rights
Copyright @2014 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Master-34312-3110202003-abstract_id.pdf - 158 KB
  2.  ITS-Master-34312-3110202003-abstract_en.pdf - 157 KB
  3.  ITS-Master-34312-3110202003-conclusion.pdf - 171 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 34.226.244.70
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2020 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan