Posted by aprill@is.its.ac.id at 20/01/2015 19:14:38  •  2503 Views


STUDI PERBANDINGAN ALIRAN ALAT UKUR DEBIT AMBANG TIPIS PENAMPANG SEGI TIGA DENGAN GABUNGAN PENAMPANG SEGI TIGA DAN SEGI EMPAT

COMPARATIVE STUDY OF FLOW BETWEEN RECTANGULAR WEIR AND COMBINATION OF TRIANGULAR AND RECTANGULAR WEIR

Author :
SUMIRMAN, EDY  ( 3111205201 )




ABSTRAK

Pelimpah ambang tipis adalah pelimpah ambang pendek dimana tidak pernah terjadi aliran hidrostatik di atasnya. Ada beberapa alat ukur aliran yang menggunakan pelimpah ambang tipis yaitu Thomson Reyboch Cipoletti dan dibedakan oleh bentuk penampangnya seperti penampang berbentuk segi tiga V-Notch segi empat rectangular trapezium Cipoletti. Bentuk pelimpah akan berpengaruh pada tinggi air diatas pelimpah. Bentuk segi tiga pada umumnya digunakan untuk pengukuran debit kecil. Alat ukur V-notch adalah alat ukur berbentuk segi tiga yang didesain dengan bentuk takik yang berbentuk seperti huruf V. Alat ukur ini menghasilkan pengukuran yang akurat untuk pengaliran debit kecil dibandingkan dengan alat ukur yang lain. Sedangkan pada pengaliran debit besar bentuk segi tiga menghasilkan muka air diatas mercu lebih tinggi dari bentuk yang lain. Pelimpah dengan penampang segi empat untuk tinggi muka air dan lebar yang sama memiliki kemampuan mengalirkan debit lebih besar dari pada penampang segi tiga. Namun ketika mengalir debit kecil pada pelimpah penampang segi empat inggi muka air di atas pelimpah terlalu kecil sehingga pengukuran menjadi tidak akurat. Penampang majemuk yang merupakan gabungan dari penampang segi tiga dan segi empat diharapkan dapat mengakomodasi kelemahan dari penampang segi empat dan segi tiga saja dalam melakukan pengukuran baik debit kecil maupun debit besar. Oleh sebab itu penulis melakukan penelitian aliran melalui pelimpah ambang tipis berpenampang majemuk yang terdiri dari penampang segi tiga dan penampang segi empat. Penelitian dilakukan mengukur aliran pada pelimpah ambang tipis berpenampang segi tiga dan majemuk yang ditempatkan pada flume di dalam laboratorium. Kecepatan aliran diukur dengan menggunakan micro ADV dan permukaan air di hulu pelimpah dan ditempat pengukuran kecepatan diukur dengan menggunakan alat Ultrasonic Water Level Recorder . Data hasil pengukuran kecepatan aliran dan tinggi muka air dianalisa dengan metode statistik deskriptif untuk mendapatkan nilai rata-rata dan simpangannya. Penelitian ini diperoleh perbandingan profil aliran antara pelimpah ambang tipis berpenampang segi tiga dan berpenampang majemuk perubahan perilaku aliran dari penampang segi tiga ke penampang gabungan ketidak-kontinyuitas hubungan antara debit aliran dan tinggi air diatas pelimpah penampang majemuk dan angka koefisien debit pelimpah penampang majemuk dengan ukuran tertentu.


ABSTRACT

Sharp crested weir is a weir with a short sill with no hydrostatic flow on the weir. There are several measurement tool using sharp crested weir such as Thompson Rehboch Cipoletti and distinguished by the shape such as triangular V-notch rectangular trapezium Cipoletti. Weir shape will affect the water level above the weir crest. The triangular shape is generally used to measure small discharge. V-notch weir is a measuring tool that is designed with a triangular shaped notch shape like the letter V. This instrument produces accurate measurements for small discharge compared to other measurement tools.While for large discharge water level for triangular shape is greater than the other forms. Weir with rectangular shape has the ability to measure greater discharge than the triangular weir. For small discharge height of water above rectangular weir crest is to small so that measurement water becomes inaccurate. Compound weir which is a combination of triangular weir and rectangular expected to accommodate the weakness of rectangular weir and a triangular weir in measuring discharge both for small and large discharge. The authors conducted a study of flow through sharp crested weir has a compound cross section consisting of a triangular cross-section and rectangular cross-section. The study was conducted by measuring the flow at the weir with thin triangles and compound shaped weir in a laboratory flume. The flow velocity was measured by using a micro ADV and surface water level in spillway upstream and velocity measuring point is measured using Ultrasonic Water Level Recorder. Flow velocity measurement data and water levels were analyzed with descriptive statistical methods to obtain an average value and deviation. This experiment resulted a comparison between the weir flow profile for thin triangles weir and compound weir changes in the flow behavior of triangular weir to the combined weir non-continuity relationship between flow rate and water level above the compound weir section and coefficients for compound section weir discharge of a certain size.



KeywordsWeir; V-notch; Compound weir; coefficient of discharge; micro ADV; Ultrasonic Water Level Recorder
 
Subject:  bendungan
Contributor
  1. Dr. techn. Umboro Lasminto, ST, M.Sc
Date Create: 12/11/2013
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Master-31103150001251
Collection ID: 31103150001251
Call Number: RTS 627.883 Sum s


Source
Master Theses of Civil Engineering, RTS 627.883 Sum s, 2015

Coverage
ITS Community

Rights
Copyright @2015 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Master-35609-3111205201-Abstract_id.pdf - 256 KB
  2.  ITS-Master-35609-3111205201-Abstract_en.pdf - 253 KB
  3.  ITS-Master-35609-3111205201-Conclusion.pdf - 392 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.196.47.128
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan