RECALCULATING AND SELECTION OF SEA WATER BOOSTER PUMP AT COOLING WATER SYSTEM PLTGU BLOCK III PT. PJB UNIT PEMBANGKITAN GRESIK

Author :
SYAFIUDIN, ARDIANZHA ( 2111 038 009 )




ABSTRAK

PT. PJB Unit Pembangkitan Gresik merupakan perusahaan yang bergerak dibidang industri pembangkitan listrik. Mengingat sangat pentingnya peralatan pompa yang digunakan untuk melayani sistem air pendingin PLTGU maka kami tertarik untuk mempelajari Pompa Sea Water Booster dimana peranan pompa ini yang cukup penting dalam Sistem Air Pendingin untuk peralatan produksi PLTGU. Penelitian ini bertujuan untuk mengetahui besar head dan kapasitas yang dibutuhkan oleh pompa sea water booster. Selain melakukan perhitungan teoritis juga dilakukan perhitungan secara numerik dengan menggunakan software Pipe Flow Expert v5.12 Setelah melakukan perhitungan ulang intalasi perpipaan pompa sea water booster dengan tujuan menentukan pemilihan pompa yang sesuai untuk instalasi sistem air pendingin tersebut. Maka pada perhitungan didapat nilai kapasitas untuk memenuhi kebutuhan Cooling Water Heat Exchanger sebesar h m3 5100 dengan Heff sebesar 11.18 m dan NPSHA sebesar 6.83 m. Perhitungan tersebut dipilih pompa jenis horizontal sentrifugal tipe double suction dengan merk TORISHIMA PUMPS.


ABSTRACT

PT. PJB Unit Pembangkitan Gresik is a company engaged in the insdutrial power plant The company activity is producing electricity for daily and industrial needs. Given the importance of pumps equipment used to serve in the cooling system so in this final project the writer are interested in discuss about the Sea Water Booster Pump. Where the role of this pump is quite important for Cooling Water System. The aim of this observation to know the head and pump capacity required by the sea water booster pump. In addition to theoritical calculations also performed numerical calculations using Pipe Flow Expert v5.12 software. After get the recalculating the installation of piping sea water booster pump with the purpose to fix selection of pumps that suitable for cooling water system istalalation. In calculation of the value obtained planning capacity of the Cooling Water Heat Exchanger needs is h m3 5100 for the Heff at 11.18 m and NPSHA of 6.83 m and from the calculation the selected pumps is horizontal centrifugal pump and types of pumps is double suction with merk of pump is TORISHIMA PUMPS.



KeywordsPompa Sea Water Booster; Sistem Air Pendingin; Cooling Water Heat Exchanger
 
Subject:  pompa sentrifugal
Contributor
  1. Dr. Ir. Heru Mirmanto, MT
Date Create: 03/09/2015
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-NonDegree-21102150001314
Collection ID: 21102150001314
Call Number: RSM 621.67 Sya p


Source
Non Degree of Mechanical Engineering, RSM 621.67 Sya p, 2015

Coverage
ITS Community

Rights
Copyright @2015 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-NonDegree-38711-2111038009-abstract_id.pdf - 493 KB
  2.  ITS-NonDegree-38711-2111038009-abstract_en.pdf - 481 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 10.199.6.2
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2021 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan