DESAIN DAN IMPLEMENTASI KONTROLER PI PADA SISTEM SUPERVISORY CONTROL AND DATA ACQUISITION SCADA UNTUK SISTEM PENGATURAN LEVEL INDEPENDEN

DESIGN AND IMPLEMENTATION PI CONTROLLER OF THE SYSTEM SUPERVISORY CONTROL AND DATA ACQUISITION SCADA FOR SYSTEM INDEPENDENT LEVEL SETTINGS

Author :
DEWANTARA, PRAYUDHA ( 2211030055 )
SANTOSO, TATANG TEGUH




ABSTRAK

Pengaturan level merupakan proses yang digunakan untuk menjaga tingkat ketinggian air agar tetap dalam kondisi set point yang telah ditentukan. Dalam penerapannya sistem ini memiliki nilai beban yang berubah-ubah apabila terjadi perubahan pada bukaan valve yang tidak sesuai dengan set point. Perubahan tersebut dapat mengakibatkan keluaran menjadi tidak sesuai dengan yang diinginkan. Oleh karena itu dirancang sebuah kontroler PI Proportional ditambah Integral untuk mengendalikan plant agar dapat menjaga kestabilan kerja dan untuk mempercepat respon. Kontroler PI Proportional ditambah Integral dalam sistem ini akan diterapkan pada sistem Supervisory Control And Data Acquisition SCADA sebagai sistem pemantauan dan pengontrolan terhadap plant. Dari hasil pengujian kontroler PI Proportional ditambah Integral dapat mengendalikan respon plant yang tidak sesuai dengan nilai set point nilai rata-rata kesalahan waktu tunak pada implementasi sebesar 16 .


ABSTRACT

Setting the level is a process used to maintain water levels for remain within a predetermined set point conditions. In application of this system has a load rating change when there is a change in the valve opening is not in accordance with the set point. Such changes may result in the output to be not in accordance with the desired Therefore designed a PI controller Proportional plus Integral to control the plant in order to maintain stability and to speed up the response work. PI controller Proportional plus Integral in this system will be applied to the system of Supervisory Control And Data Acquisition SCADA as a monitoring and control system of the plant. From the test results the PI controller Proportional plus Integral in order to control plant responses that do not correspond to the set point value the average value of the steady state error at the time of implementation of 1.6.



KeywordsKontroler PID, Level, SCADA
 
Subject:  PID controllers
Contributor
  1. Slamet Budiprayitno, ST., MT
Date Create: 01/07/2014
Type: Text
Format: PDF
Language: Indonesian
Identifier: ITS-NonDegree-22102150001246
Collection ID: 22102150001246
Call Number: RSE 629.89 Dew d


Source
Non Degree Of Electrical Engineering RSE 629.89 Dew d, 2015

Coverage
ITS Community

Rights
Copyright @2015 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-NonDegree-38641-2211030055-2211030091-Abstract_id.pdf - 85 KB
  2.  ITS-NonDegree-38641-2211030055-2211030091-Abstract_en.pdf - 85 KB
  3.  ITS-NonDegree-38641-Abstract_id.pdf - 360 KB
  4.  ITS-NonDegree-38641-Abstract_en.pdf - 359 KB
  5.  ITS-NonDegree-38641-Conclusion-391898.pdf - 383 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.196.47.128
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan