PEMBUATAN DAN PENGUKURAN PEMAKAIAN DAYA LISTRIK DI TIGA LAB ELEKTRO INDUSTRI PENS-ITS DAN MONITORING JARAK JAUH

Author :
Abidin, Khairul ( 7306030021 )




ABSTRAK

Kebutuhan energi listrik pada rumah tangga meningkat dan harga energi listrik mahal yang menyebabkan pembayaran energi listrik besar. Oleh karena itu perlu dilakukan penghematan pemakaian daya dengan monitoring pemakaian daya arus tegangan dan cos phi. Dengan adanya monitoring parameter daya ini diharapkan dapat mengetahui berapa penggunaan daya tegangan arus dan cos phi pada setiap bulannya. Monitoring parameter daya ini menggunakan PowerLogic PM810 fungsi dari alat tersebut adalah membaca parameter daya seperti tegangan arus cos phi dan daya. Dengan menggunakan mikrokontroller Atmega 162 hasil dari pembacaan parameter daya akan disimpan dengan cara dari mikrokontroller melakukan request ke power logic dengan bantuan sofware Code Vision AVR menggunakan bahasa C proses baca tulis antara mikro dengan PowerLogic dapat dilakukan. Komunikasi antara mikrokontroller Atmega 162 dengan PowerLogic PM810 tidak akan terwujud jika tidak ada converter RS 485 to RS 232 karena pada Power Logic memiliki serial RS 485 sedangkan pada mikrokontroller sendiri memiliki serial RS 232.


ABSTRACT

Electrical energy needs in the household energy prices and increased electricity costs that cause the payment of electricity. Therefore the savings should be done with the power usage monitoring power flow voltage and cos phi. With the power of monitoring this parameter can be expected to know how the use of power voltage current and cos phi in each month. Monitoring this parameter power use PowerLogic PM810 the function of the tool is the power of the parameters such as voltage current power and cos phi. By using mikrokontroller Atmega 162 results from the reading of the parameters will be stored with the power of how to request mikrokontroller logic to power with the help of software Code Vision AVR C language using the read - write the micro can be done with PowerLogic. Communication between mikrokontroller Atmega 162 with PowerLogic PM810 will not be realized if there is no converter RS 485 to RS 232 as the Power Logic has a serial RS 485 while the mikrokontroller have their own serial RS 232.



KeywordsPowerLogic PM810, AVR, Mikrokontroller Atmega 162
 
Subject:  Mikrokontroller
Contributor
  1. Ir. Gigih Prabowo, MT
  2. Ir. Era Purwanto, M.Eng
Date Create: 23/03/2010
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-NonDegree-3100010037483
Collection ID: 3100010037483
Call Number: RSEP 629.89 Abi p


Source
Nondegree, Electronics Engineering Polytechnic RSEP 629.89 Abi p, 2009

Coverage
ITS Community Only

Rights
Copyright @2009 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-NonDegree-8940-7306030021-Abstract_in.pdf - 128 KB
  2.  ITS-NonDegree-8940-7306030021-Abstract_en.pdf - 128 KB
  3.  ITS-NonDegree-8940-7306030021-Conclusion.pdf - 85 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 35.175.248.25
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2019 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan