Posted by dee@its.ac.id at 19/10/2013 12:35:57  •  1664 Views


STUDI KASUS PENGHILANGAN KADAR AIR PADA TRAFO DENGAN MENGGUNAKAN RUANG HEATER DAN SISTEM INJEKSI PT. PLN PERSERO JASA DAN PRODUKSI

REMOVAL CASE STUDY LEVEL OF WATER ON TRANSFORMATOR USING HEATER ROOM AND INJECTION SYSTEM PT. PLN PERSERO SECVICE AND PRODUCTION

Author :
INDRAWAN, DENDY BAGUS  ( 6408030001 )
PRASTYO, YOGI




ABSTRAK

Transformator merupakan suatu komponen yang vital dalam pendistribusian listrik. Fungsi dari tranformator sendiri adalah menaikkan tegangan dan menurunkan tegangan. Tujuan penulisan studi kasus ini adalah untuk mengetahui hasil dari transformator yang telah di rekondisi haruslah mempunyai nilai tahanan isolasi yang bagus. Nilai tahanan isolasi berpengaruh dari kadar air di dalam trafo. Alat yang digunakan untuk menghilangkan kadar air ada 2 macam yaitu dengan menggunakan ruang heater oven dan sistem injeksi. Ruang heater oven merupakan sebuah ruangan yang fungsinya untuk menghilangkan kadar air pada trafo dengan 46 alat pemanas terpasang di dalamnya. Ruang heater ini mampu memuat hingga 8 unit trafo di dalamnya dan bekerja dengan tegangan 380 V. Suhu yang dihasilkan oleh pemanas bisa mencapai 100C saat pengoperasiannya. Terdapat sistem kontrol sebagai pengontrol suhu yang bekerja secara otomatis apabila suhu di dalam ruangan mencapai 100 C heater akan mati secara otomatis dan apabila suhu di dalam ruangan menurun hingga 65C heater akan menyala secara otomatis. Sistem injeksi merupakan sebuah alat yang fungsinya sebagai penghilang kadar air dengan memanfaatkan panas yang disebabkan oleh arus beban penuh pada sisi sekunder yang di hubung singkatkan. Penginjekkan dilakukan dengan menginjekkan tegangan 380 V pada sisi primer dan menghubung singkatkan sisi sekunder.


ABSTRACT

Transformer is a vital component which distribute electric wave. The use of transformer is for up or down voltage. The object of this research case process of writing is to find out the result of recondition transformers should have a good value of insulation resistance. The value of insulation resistance adapted by the level of water in the transformer. There are two the tools for reduce the level of water are heater room oven and injection system. The direction of Heater room oven is a room for cleaning up the level of water in the transformer with 46 heaters applied in. This heater room can load 8 tranformers an could run with 380 V. The heater can reach 100C temperature when it runs. There is a control system that controls temperature automatically if the temperature reach 100C the heater will be shut down and if the temperature reduce until 65C the heater will be turn on again automatically. Injection system is a tool for eliminating the level of water using heat that caused by the current of full resistance in the the secondary side that short-circuit. Injectioning is doing with inject voltage 380V at primary side and short-circuit secondary side.



KeywordsTrafo; Ruang heater; Sistem injeksi; Tahanan Isolasi
 
Subject:  Termodinamika
Contributor
  1. Urip Mudjiono, ST, MT
Date Create: 26/07/2011
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-NonDegree-64002130000267
Collection ID: 64002130000267
Call Number: 621.402 5 Ind s


Source
Non Degree of Ship Electricity Engineering, 621.402 5 Ind s, 2013

Coverage
ITS Community

Rights
Copyright @2013 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-NonDegree-27433-6408030001-6408030002-Abstract_id.pdf - 350 KB
  2.  ITS-NonDegree-27433-6408030001-6408030002-abstract-en.pdf - 350 KB
  3.  ITS-NonDegree-27433-6408030001-6408030002-Conclusion.pdf - 346 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 18.206.194.83
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2019 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan