APLIKASI DOUBLE COUPLER SERAT OPTIK MULTIMODE SEBAGAI SENSOR KEMOLARAN LARUTAN NACL

APPLICATION OF OPTICAL FIBER DOUBLE COUPLER MULTIMODE AS MOLARITY SENSOR OF NaCl SOLUTION

Author :
MEGAWATI, RETNO FATMA  ( 1109100035 )




ABSTRAK

Sensor kemolaran larutan NaCl telah dibuat dari directional double coupler serat optik multimode. BF5R-D1-N digunakan sebagai sumber cahaya yang berasal dari LED merah dengan panjang gelombang 660 nm dan phototransistor sebagai detektor. Variasi kemolaran larutan NaCl 0-5 M dan variasi jenis kupasan diberikan dalam penelitian ini. Prinsip kerja dari sensor ini adalah mendeteksi rugi daya pada setiap adanya perlakuan. Hasilnya adalah rugi daya yang terdeteksi berbanding lurus dengan molaritas dan panjang kupasan. Probe sensor dengan kupasan pada daerah jaket dan cladding lebih sensitif dibandingkan dengan probe sensor dengan kupasan hanya pada daerah jaket.


ABSTRACT

Molarity sensor of NaCl solution has been made of the double directional coupler multimode optical fiber. BF5R-D1-N is used as the light source coming from a red LED with a wavelength of 660 nm and a phototransistor as the detector. Molarity variation of NaCl solution 0-5 M and variation of types of peels are given in this research. The working principle of this sensor is to detect the power loss in each treatment. The result is a power loss is detected directly proportional to the length of molarity and peeling. Probe sensor with peeling on coating and cladding regions are more sensitive than the sensor probe with peeling only in regions.



KeywordsSerat Optik;Directional Double Coupler;Kemolaran LarutanNaCl
 
Subject:  Optika
Contributor
  1. Drs. Gatut Yudoyono,M.T.
Date Create: 15/07/2013
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-11001140004544
Collection ID: 11001140004544
Call Number: RSFi 681.25 Meg a


Source
Undergraduate Thesis of Physics, RSFi 681.25 Meg a, 2014

Coverage
ITS Community

Rights
Copyright @2014 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-29983-1109100035-Abstract_id.pdf - 197 KB
  2.  ITS-Undergraduate-29983-1109100035-Abstract_en.pdf - 190 KB
  3.  ITS-Undergraduate-29983-1109100035-Conclusion.pdf - 192 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 23.23.50.247
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2016 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan