Posted by aprill@is.its.ac.id at 19/02/2014 08:42:26  •  1069 Views


PEMODELAN SISTEM DISTRIBUSI RADIAL UNTUK STUDI ALIRAN DAYA HARMONISA TIGA FASA

MODELING OF UNBALANCE RADIAL DISTRIBUTION SYSTEM TO CALCULATE THREE PHASE HARMONIC POWER FLOW

Author :
DANYAL, AKHMAD  ( 2211105057 )




ABSTRAK

Penyebaran harmonisa dalam suatu sistem distribusi tenaga listrik dapat menimbulkan rugi-rugi dalam penyaluran energi listrik dan juga menyebabkan kerusakan pada peralatan listrik. Salah satu penyebab munculnya distorsi harmonisa dalam sistem distribusi adalah beban nonlinier. Dengan meninjau akibat yang ditimbulkan dari penyebaran harmonisa maka diperlukan suatu metode untuk memodelkan sistem distribusi dan menganalisa penyebaran harmonisa dalam sistem sistem distribusi sehingga besar dan lokasi harmonisa dapat diketahui. Metode forward-backward adalah salah satu metode yang dapat digunakan untuk melakukan studi aliran daya harmonisa dalam sistem distribusi khususnya sistem distribusi radial. Metode ini memanfaatkan vektor dalam bentuk matrik untuk mengetahui aliran arus injeksi dalam saluran distribusi dan juga matrik dari impedansi saluran yang digunakan untuk perhitungan tegangan harmonisa di tiap bus. Metode forward-backward dapat digunakan untuk studi aliran daya harmonisa sistem distribusi satu fasa tiga fasa seimbang dan tiga fasa tak seimbang. Dari hasil pengujian sistem distribusi 20 bus tiga fasa tak seimbang dengan software ETAP sebagai pembanding didapatkan nilai error untuk fasa A sebesar 770 untuk fasa B sebesar 572 dan untuk fasa C sebesar 511.


ABSTRACT

As harmonics distortion propagate trough the distribution system it would result in losses increases and possible cause equipment loss of life. The use of nonlinear loads in distribution system is one cause harmonics distortion. Reviewing the effects caused by harmonics distortion then harmonic analysis methods are used to investigate the harmonics propagation in the distribution system. One of the methods that can be used to calculate the harmonics value is forward-backward method the backward sweep is used to build the relationship between branch currents and bus current injections and the forward sweep can use to calculate bus voltage. This method can be used to calculate the harmonics value in single phase and multiphase radial distribution system. From the test system for 20 bus unbalance radial distribution system this method has error value 7.70 for phase A 5.72 for phase B and 6.11 for phase C.



KeywordsRadial distribution system; harmonics; forward-backward
 
Subject:  Harmonik distribusi tenaga listrik (gelombang listrik)
Contributor
  1. Prof. Ir. Ontoseno Penangsang, M.Sc., Ph.D
  2. Dimas Anton Asfani, ST., MT., Ph.D
Date Create: 03/07/2013
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-22001140004466
Collection ID: 22001140004466
Call Number: RSE 621.319 Dan p


Source
Undergraduate Thesis of Electrical Engineering, RSE 621.319 Dan p, 2014

Coverage
ITS Community

Rights
Copyright @2014 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-29795-2211105057-Abstract_id.pdf - 249 KB
  2.  ITS-Undergraduate-29795-2211105057-Abstract_en.pdf - 249 KB
  3.  ITS-Undergraduate-29795-2211105057-Conclusion.pdf - 255 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 18.207.106.142
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2020 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan