ITS » Undergraduate Theses » Teknik Elektro - Ekstensi
Posted by aprill@is.its.ac.id at 03/10/2014 16:11:27  •  838 Views


PROTEKSI ARUS LEBIH YANG ADAPTIF PADA SISTEM DISTRIBUSI DENGAN PEMBANGKIT TERSEBAR

ADAPTIVE OVERCURRENT PROTECTION OF DISTRIBUTION SYSTEM WITH DISTRIBUTED GENERATION

Author :
WIBISONO, EDO HARWINDO  ( 2210106033 )




ABSTRAK

Perkembangan teknologi pembangkit tenaga listrik sudah semakin meningkat. Apalagi dengan berkembangnya pembangkit distribusi yang dapat bekerja pada mode Islanded. Namun demikian pengaman arus lebih masih memiliki masalah pada perbedaan arus gangguan ketika sistem distribusi terhubung dengan grid dan ketika dalam keadaan Islanded. Oleh sebab itu pada tugas akhir ini mengusulkan penggunaan metode pengaman yang adaptif yang memanfaatkan informasi lokal untuk mengatasi kendala pada pengaman arus lebih di sistem distribusi dengan pembangkit tersebar. Karakteristik trip pada rele diupdate dengan mengetahui kondisi pengoprasian terhubung grid atau island dan bagian gangguannya. Dalam hal ini bagian yang mengalami gangguan juga dideteksi menggunakan karakteristik waktu arus lebih dari rele pengaman. Hasil simulasi akan ditunjukan melalui simulasi ETAP 7.0. Dari hasil analisis menunjukan bahwa kondisi pengoprasian dan pada bagian gangguan dapat diidentifikasi dengan tepat. Maka pengaturan sistem pengaman dapat diupdate untuk menyelesaikan masalah gangguan dengan lebih cepat.


ABSTRACT

The development of power generation technology is increasing.. Especially the development of power distribution that can work on Islanded mode. However overcurrent protection still have problems on the difference distribution system fault current when connected to the grid and Islanded conditions. However this final project proposes the use of adaptive protection using local information to overcome the challenges of the overcurrent protection in distribution systems with distributed generation. The trip characteristics of the relays are updated by detecting operating states grid connected or island and the faulted section. In this case faulted section detection using time overcurrent characteristics of the protective relays. Simulation results will be shown by simulation of ETAP 7.0. Simulation results show that the operating state and faulted section can be correctly identified. Then the protection system settings can be updated to clear the faults faster.



Keywordsadaptive protection; protection relay; distributed generation
 
Subject:  Distribusi tenaga listrik
Contributor
  1. Dr. Ardyono Priyadi, ST., M.Eng.
  2. Dr. Dimas Anton Asfani, ST., MT.
Date Create: 02/07/2013
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-22001140005593
Collection ID: 22001140005593
Call Number: RSE 621.319 Wib p


Source
Undergraduate Theses of Electrical Engineering, RSE 621.319 Wib p, 2014

Coverage
ITS Community

Rights
Copyright @2014 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-32107-2210106033-Abstract_id.pdf - 196 KB
  2.  ITS-Undergraduate-32107-2210106033-Abstract_en.pdf - 195 KB
  3.  ITS-Undergraduate-32107-2210106033-Conclusion.pdf - 199 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 52.23.234.7
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2019 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan