ITS » Undergraduate Theses » Teknik Lingkungan S1 Posted by dewi007 at 19/12/2008 10:43:41 • 15631 Views
PERENCANAAN BOEZEM SALURAN PRIMER
WONOREJO UNTUK MEREDUKSI PENCEMARAN
PANTAI TIMUR SURABAYA
DESIGN OF WONOREJOS PRIMARY CHANNEL BOEZEM TO REDUCE SURABAYAS EAST COAST POLLUTION
Author : Yuliandhika, Rendy
ABSTRAK
Pantai timur Surabaya merupakan muara saluran primer
Wonorejo yang menerima air hujan dan air buangan domestik dan
non domestik yang dihasilkan dari sebagian kecamatan Rungkut
Tenggilis Mejoyo Wonocolo Gayungan Jambangan dan
Wonokromo. Saat ini pada saluran Wonorejo kondisinya berbau
dan berwarna hitam pekat hal ini menandakan telah terjadi
pencemaran untuk mengatasi masalah tersebut salah satunya
dengan merancang sebuah bozem yang berfungsi sebagai kolam
wetland dan kolam stabilisasi.
Pada tugas akhir ini akan merencanakan sebuah bozem
yang berfungsi sebagai kolam wetland dan kolam stabilisasi.
Kolam yang digunakan untuk mereduksi bahan pencemar yang
terkandung pada saluran primer Wonorejo adalah kolam free
water surface wetland dan kolam fakultatif. Luas lahan 20 ha
yang tersedia mampu menurunkan BOD sebesar 70 TSS
sebesar 49 dan E. Coli sebesar 9999 . Effluent boezem yang
menggunakan kolam free water surface wetland dan kolam
stabiliasasi adalah BOD 19 mgl TSS 166 mgl dan E.coli
535 MPN100 ml .
ABSTRACT
East coast of Surabaya is the end of Wonorejos primary
channel which receive stormwater and wastewater domestic and
non domestic from Rungkut Tenggilis Mejoyo Wonocolo
Gayungan Jambangan dan Wonokromo district. Nowdays
Wonorejos primary channel condition smell bad and the water is
black. It shows that Wonorejos primary channel has been
polluted. This problem con be solved by designing a boezem as a
wetland and stabilization pond.
This final project is going to design a boezem as a
wetland and stabilization pond. The ponds that will be used to
reduce pollutants contained in Wonorejos primary channel are
free water surface wetland and facultative ponds. 20 ha areas of
ponds reduce 70 of BOD 49 of TSS and 9999 of E. Coli.
Effluent of this boezem using free water surface wetland and
facultative ponds contain 19 mgl of BOD 166 mgl of TSS and
535100 ml MPN of E.coli.
Keywords:
Saluran primer Wonorejo; boezem; free water surface wetland dan kolam fakultatif
Rights Copyright @2007 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library