ANALISA TINGKAT KEBISINGAN PADA MESIN KOMPRESOR UNIT CO2 PABRIK I PT.PETROKIMIA GRESIK PERSERO UNTUK MEMPREDIKSI TINGKAT KEMUNDURAN PENDENGARAN KARYAWAN

ANALYSIS OF NOISE LEVEL COMPRESOR MACHINE IN THE MANUFACTURE I CO2 UNIT PT PETROKIMIA GRESIK Persero TO PREDICTED NOISE HEARING LOSS OF EMPLOYMEENT

Author :
Aminullah, Nasrun 




ABSTRAK

Pengoperasian mesin kompresor yang terdapat di PT.Petrokimia Gresik. umumnya adalah mesin-mesin besar yang dapat menimbulkan tingkat kebisingan yang tinggi. Dimana tingkat kebisingan yang tinggi sangat besar pengaruhnya terhadap manusia. Khususnya pada tingkat kemunduran pendengaran manusia Upaya menurunkan tingkat kebisingan bertujuan untuk melindungi para pekerja yang sering berada di sekitar area ruang mesin kompresor dari gangguan pendengaran. Tahapan yang dilakukan untuk menganalisa tingkat kebisingan adalah pengukuran TTB pada sumber bising dan pada ruang penerima NIHL Noise Induced Hearing Loss AIHL Age Induced Hearing LossHLTotal serta hasil kuesioner yang telah diisi oleh pekerja. Hasil Dari penelitian ini adalah area ruang mesin kompresor tersebut memiliki tingkat kebisingan maksimum 92.5 dBA sedangkan tingkat kebisingan minimumnya adalah 88.1 dBA dengan tingkat tekanan bunyi rata-rata yaitu 90.55 dBA sedang HLTotal mulai usia 40 tahun dengan lama noise exposure minimal 15 tahun karyawan akan mengalami kemunduran pendengaran yang signifikan Hearing Loss 25 dB terutama untuk frekuensi tinggi Audiometri 4000 6000. Ini artinya sensitifitas sistim pendengaran karyawan akan menurun untuk frekuensi tinggi Audiometri.


ABSTRACT

Generally operation of compressor machine in the PT Petrokimia Gresik is big machines which caused high noise level. It was caused extreme effect for human. Especially its hearing level. Purpose of noise level decrease is protect the workers in the surrounding of compressor area from hearing noise oftenly. First step to start analyze noise level is measure TTB of noise source and control room NIHLNoise Induced Hearing Loss AIHL Age Induced Hearing Loss HLTotal Hearing Loss Total also the result questionaire which falled by them. As the result of the research state if the maximum noise level in the surrounding of compressor area is 92.5 dBA and the minimum is 88.1 dBA. For the sound level average is 90.55 dBA and the HLTotalfor range age which start from 40 years with at least noise exposure as long as 15 years which caused hearing impairment of them significantly Hearing Loss25 dB especially for high frekuensi 4000 6000 Hz. Its means hearing impairment sensitivity feel down for high frekuensi Audiometri



KeywordsTingkat Kebisingan; Kompresor; Hearing Loss
 
Subject:  Kebisingan
Contributor
  1. Ir. Supriyanto, M.Sc
    Ir. Tutug Dhanardono
Date Create: 27/02/2009
Type: Text
Format: pdf.
Language: Indonesian
Identifier: ITS-Undergraduate-3100008030930
Collection ID: 3100008030930
Call Number: RSF 620.23 Ami a


Source
Undergraduate Theses of Physic Engineering, RSF 620.23 Ami a, 2007

Coverage
ITS Community Only

Rights
Copyright @2007 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Summary ]

ITS-Undergraduate-3100008030930-3631.pdf




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 3.234.250.24
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2020 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan