Posted by davi at 06/02/2009 10:51:17  •  5917 Views


PERANCANGAN SISTEM KONTROL PADA INFUSION PUMP MERK BECTON DICKINSON TYPE VIP II BERBASIS MIKROKONTROLER

DESIGN OF CONTROL SYSTEMS AT INFUSION PUMP MERK BECTON DICKINSON TYPE VIP II BASE ON MIKROKONTROLER

Author :
Maulana, Arfan 




ABSTRAK

Infusion Pump adalah salah satu peralatan kesehatan untuk therapy yang digunakan pada beberapa rumah sakit. Biasanya alat ini digunakan pada ruang perawatan intensive dan kedaruratan ICU CVCU NICU PICU IRD dan CO. Alat ini berfungsi untuk memberikan nilai keakuratan serta keamanan dalam pemberian dosis cairan infuse ke pasien yang biasanya diberikan dengan pengaturan secara manual. Infusion pump merk Becton Dikinson Type VIP II adalah salah satu infusion pump yang mengalami kerusakan dan dilakukan perancangan ulang untuk sistem kontrolnya. Pada perancangan yang dilakukan ini dengan berbasis mikrokontroler yang bertujuan untuk pengaturan nilai flow ratenya serta diharapkan mempunyai nilai keakuratan yang optimal. Dengan menggunakan IDA-4 sebagai kalibrator dihasilkan nilai koreksi terendah 3.70 untuk setting flow rate 10mljam dan tertinggi 7.65 untuk setting flow rate 150 mljam. Untuk tingkat akurasi rata-rata 6.1. Sedangkan ketidakpastian terendah 1.03mljam untuk flow rate 60mljam sedangkan yang tertinggi 2.25ml untuk flow rate 150mljam.


ABSTRACT

Infusion Pump is one of the equipments of health for used therapy in some hospital. Usually this appliance is used in intensive treatment and emergency room ICU CVCU NICU PICU IRD and CO. This Appliance function to assign value accuracy and security in giving dilution dose of infuse to patient which is usually given with arrangement manually. Infusion Pump with merk Becton Dikinson Type VIP II is one of the infusion pump which is can damage and done by scheme repeat for its control systems. This design based on microcontroller which aim to arrangement of flow rate value and also expected to have optimal accuracy value. By using IDA-4 as calibrator the result of calibrating are lowest corrective value 3.70 for the setting of flow rate 10mlhour and highest 7.65 for the setting of rate flow 150 mlhour. For mean accuracy 6.1. While lowest uncertainty is 1.03mlhour for flow rate 60mlhour and highest is 2.25ml for flow rate 150mlhour.



Keywordsflow rate; infusion pump; mikrokontroller
 
Subject:  Pompa
Contributor
  1. Dr. Bambang L. Widjiantoro, ST, MT
Date Create: 06/02/2009
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-3100008032845
Collection ID: 3100008032845
Call Number: RSF 629.895 Mau p


Source
Undergraduate Thesis, Physical Engineering Department, RSF 629.895 Mau p, 2008

Coverage
ITS Community Only

Rights
Copyright @2008 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Summary ]

ITS-Undergraduate-3100008032845-3520.pdf




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 34.204.176.189
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2019 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan