SIMULASI PENINGKATAN KUALITAS DAYA LISTRIK PADA JARINGAN DISTRIBUSI SURABAYA DENGAN KONDISI BEBAN BERUBAH-UBAH

Author :
Irawan, Endy Rahmat 




ABSTRAK

Kualitas daya dalam sistem tenaga listrik merupakan hal yang penting untuk menjaga stabilitas sistem tenaga listrik. Untuk memperbaiki kualitas daya salah satunya dengan pemasangan kapasitor bank sehingga dapat meminimalkan rugi-rugi jaringan memperbaiki faktor daya dan juga memperbaiki profil tegangan. Pada tugas akhir ini bertujuan untuk memperbaiki kualitas daya terutama memperbaiki profil tegangan dengan pemasangan kapasitor bank di penyulang Tanjung Priok gardu induk Morokrembangan. Hasil akhir menunjukkan adanya penurunan rugi-rugi sampai 24 kW88 kVar dan faktor daya meningkat menjadi 0871 saat pemasangan kapasitor pukul 04.00 WIB. Ketika pemasangan kapasitor pukul 19.00 WIB rugi-rugi turun sampai 57 kW214 kVar serta faktor daya meningkat menjadi 0861. Simulasi load flow dilakukan menggunakan software ETAP Power Station.


ABSTRACT

Power quality on the power system is the important factor in keep the stability of system. To fix the power quality one of them with installing capasitor bank so that minimize the losses fix power factor and also to fix voltage profile. The purpose of this final project is to fix power quality especially voltage profile by installing capasitor bank on feeder Tanjung Priok substation Morokrembangan. Final result shows that the losses decrease until 24 kW88 kVar and power factor increase become 0871 when installed capacitor at 04.00 WIB. When installed capacitor at 19.00 WIB the losses decrease until 57 kW214 kVar and power factor increase become 0861. The load flow simulation has been done using ETAP Power Station software.



KeywordsKapasitor bank; daya reaktif; aliran daya dan kapasitas kapasitor
 
Subject:  Distribusi Tenaga listrik
Contributor
  1. Prof. Ir. Ontoseno Penangsang, M.Sc, Ph.D
Date Create: 08/05/2009
Type: Text
Format: pdf.
Language: Indonesian
Identifier: ITS-Undergraduate-3100008032873
Collection ID: 3100008032873
Call Number: RSE 621.319 Ira s


Source
Undergraduate Theses of Electrical Engineering, RSE 621.319 Ira s, 2008

Coverage
ITS Community Only

Rights
Copyright @2008 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Summary ]

ITS-Undergraduate-3100008032873-3975.pdf




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 107.22.86.42
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2016 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan