EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya


Kampus ITS Sukolilo - Surabaya 60111

Phone : 031-5921733 , 5923623
Fax : 031-5937774
E-mail : libits@its.ac.id
Website : http://library.its.ac.id

Support (Customer Service) :
timit_perpus@its.ac.id








Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Taufik Rachmanu


Dewi Eka Agustina


Ansi Aflacha Putri


Tondo Indra Nyata


Aprillia Tri Wulansari


Moh. Fandika Aqsa




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely
Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

Still Confuse?
Please read our User Guide

Keyword
Mode
Expanded Search (for Free text search only)
 
OR You May Search Our Knowledges Using Google Customize Search :

Custom Search

ITS » Undergraduate Theses » Teknik Kes &Keselaman Kerja - D4
Posted by dewi@its.ac.id at 08/03/2010 16:50:48  •  2057 Views


EVALUASI FIRE EMERGENCY RESPON PLAN, APAR DAN PERANCANGAN HIDRANT SYSTEM DI PT. CIPTA BUSANA JAYA

FIRE EMERGENCY RESPONSE PLAN, APAR EVALUATION AND HYDRANT SYSTEM DESIGNING IN PT. CIPTA BUSANA JAYA, SIDOARJO

Created by :
MEGANTARA, DIMAS ADITYA ( 6505040035 )



Subjectpintu darurat
Alt. Subject Fire extinction
KeywordSarana evakuasi
pintu darurat
APAR

Description:

PT. Cipta Busana Jaya merupakan industri yang bergerak dalam usaha garmen. Proses produksi yang dihasilkan dari industri ini tiap harinya  16000 pieces, berarti perusahaan ini memiliki bahan baku yang berupa tekstil dalam jumlah yang cukup besar sehingga perusahaan ini dapat dikategorikan sebagai bangunan yang memiliki tingkat Bahaya kebakaran sedang (ordinary/moderate hazard) berdasarkan NFPA 10 tahun 1998. Sistem instalasi penanggulangan kebakaran yang terdapat pada PT. Cipta Busana Jaya hamya terdapat APAR dan Prosedur Fire Emergency Respon Plan. Penelitian ini dimulai dengan pengambilan data-data berupa jumlah APAR dan sarana escape yang sudah ada di PT. Cipta Busana Jaya. Evaluasi APAR dimulai dengan mengevaluasi penempatan dan pengadaan APAR yang telah ada dan membandingkan dengan peraturan yang ada (PERMENAKERTRANS RI NO.04/MEN/1980 dan NFPA 10 tahun 1998). Evaluasi Fire Emergency Respon Plan dimulai dengan mengevaluasi lebar pintu darurat, jumlah pintu darurat, escape route dan letak assembly area berdasarkan Perda DKI Jakarta No.3 Tahun 1992 dan Life Safety Code, NFPA No. 101. Apabila hasil evaluasi terhadap APAR dan Fire Emergency Respon Plan terjadi ketidaksesuain, maka dilakukan perancangan ulang. Untuk perancangan hydrant system dimulai dengan melakukan perhitungan jumlah pilar hydarnt yang dibutuhkan, jangkauan pilar hydrant, luas bak penampung air hydrant dan perhitungan daya pompa yang dibutuhkan. Dari hasil penelitian ini bahwa jumlah APAR yang dibutuhkan PT. Cipta Busana Jaya berdasarkan PERMENAKERTRANS RI NO.04/MEN/1980 adalah 54 buah dengan jenis APAR sementara berdasarkan NFPA 10 tahun 1998 adalah 38 buah. Untuk perhitungan Fire Emergency Respon Plan diperoleh bahwa jumlah pintu darurat di PT. Cipta Busana Jaya adalah 20 pintu exit dan Jumlah assembly area hasil perancangan ada 4 area. Untuk perhitungan hydrant system diperoleh hasil ; jumlah pilar hydrant sebanyak 4 buah, dengan jarak jangkauan hydrant secara horizontal 97m dan vertical 24,46m., volume air hidrant yang dibutuhkan sebesar 56,79m3 dan volume bak reservoir sebesar 75,176 m3 dan Daya air yang dibutuhkan pompa sebesar 53,77 hp.


Alt. Description

PT. Cipta Busana Jaya is the garmen industry. Everyday this industry produce  16000 pieces of cloth. It mean this industry have a lot of fabric material, so this industry can be categorized as moderate fire danger potential building based on NFPA 10 1998 edition. Fire protection system in PT. Cipta Busana Jaya is only has APAR and Fire emergency respon plan. The research started with colecting the number of APAR and escape means data in PT. Cipta Busana Jaya. Evaluation APAR started with evaluate a placement and the number of APAR and compare with PERMENAKERTRANS RI NO.04/MEN/1980 and NFPA 10 year 1998. Evaluation Fire Emergency Respon Plan started with evaluate fire exit width, number of fire exit, escape route, and location assembly area point based on Perda DKI Jakarta No.3 year 1992 and Life Safety Code, NFPA No.101. If the result of evaluation APAR and emergency respon plan is not fulfill condition so we must redesign action. In designing hidrant system started with calculate the number of pillar hydrant, range of pillar hydrant, wide of reservoir for hydrant system and calculate pump capacity. The result from research that the number of APAR based on PERMENAKERTRANS RI NO.04/MEN/1980 is 54, and the number of APAR based on NFPA 10 year 1998 is 38. The result from calculation fire emergency respon plan that the number of fire exit in PT. Cipta Busana Jaya is 20 fire exit and 4 assembly area point. For calculation hydrant system, the result that 4 pillar hydrant with the horizontal range approximately is about 97m and vertical range approximately is about 24,46m, hydrant volume is 56,79m3 and reservoir volume is 75,176 m3 , and water capacity for pump is 53,77 hp.

Contributor:
  1. Priyo Agus S, ST.
  2. Pranowo Sidi, ST.,MT.
Date Create:08/03/2010
Type:Text
Format:pdf.
Language:Indonesian
Identifier:ITS-Undergraduate-3100010037385
Collection ID:3100010037385
Call Number:RSPP 628.925 Meg e


Source :
Undergraduate Theses of Health and Safety Engineering, RSPP 628.925 Meg e, 2009

Coverage :
ITS Community Only

Rights :
Copyright @2009 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library


Publication URL :
http://digilib.its.ac.id/evaluasi-fire-emergency-respon-plan-apar-dan-perancangan-hidrant-system-di-pt-cipta-busana-jaya-8738.html




[ Free Download - Free for All ]

  1.  ITS-Undergraduate-8738-6505040035-Cover_id.pdf - 105 KB
  2.  ITS-Undergraduate-8738-6505040035-Cover_en.pdf - 66 KB
  3.  ITS-Undergraduate-8738-6505040035-Approval_Sheet.pdf - 157 KB
  4.  ITS-Undergraduate-8738-6505040035-Abstrak_id.pdf - 165 KB
  5.  ITS-Undergraduate-8738-6505040035-Abstract_en.pdf - 164 KB
  6.  ITS-Undergraduate-8738-6505040035-Preface.pdf - 159 KB
  7.  ITS-Undergraduate-8738-6505040035-Table of Content.pdf - 163 KB
  8.  ITS-Undergraduate-8738-6505040035-Ilustration.pdf - 157 KB
  9.  ITS-Undergraduate-8738-6505040035-Tables.pdf - 157 KB
  10.  ITS-Undergraduate-8738-6505040035-Enclosures.pdf - 163 KB
  11.  ITS-Undergraduate-8738-6505040035-Chapter1.pdf - 171 KB
  12.  ITS-Undergraduate-8738-6505040035-Conclusion.pdf - 169 KB

[ FullText Content - Please, register first ]

  1. ITS-Undergraduate-8738-6505040035-Chapter2.pdf - 459 KB
  2. ITS-Undergraduate-8738-6505040035-Chapter3.pdf - 195 KB
  3. ITS-Undergraduate-8738-6505040035-Chapter4.pdf - 266 KB
  4. ITS-Undergraduate-8738-6505040035-Enclosure.pdf - 656 KB



Give your Comment here...


 10 Similar Document...



 10 Related Document...

     No related subject found !




HELP US !
You can help us to define the exact keyword for this document by clicking the link below :

APAR , Sarana , Sarana evakuasi , darurat , evakuasi , pintu , pintu darurat



POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan




49434600


Visitors Today : 1
Total Visitor : 2515713

Hits Today : 11895
Total Hits : 49434600

Visitors Online: 1


Calculated since
16 May 2012

You are connected from 10.199.13.5
using CCBot/2.0 (http://commoncrawl.org/faq/)


ITS Digital Repository Feeds



Copyright © ITS Library 2006 - 2014 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan