PERANCANGAN SISTEM DISTRIBUSI AIR PEMADAM KEBAKARAN MENGGUNAKAN SOFTWARE PIPE FLOW EXPERT DAN SOFTWARE PYROSIM STUDI KASUS DI BANDARA INTERNASIONAL JUANDA SURABAYA

DESIGN OF FIRE WATER DISTRIBUTION SYSTEM USING PIPE FLOW EXPERT SOFTWARE AND PYROSIM SOFTWARE Case Study in Juanda International Airport

Author :
MAULANA, FABRIZIO  ( 2105109605 )




ABSTRAK

Sistem distribusi air pemadam kebakaran merupakan salah satu bagian penting dari instalasi gedung. Perancangan sistem ini dilakukan dengan perhitungan yang tepat sesuai dengan struktur desain serta fungsi gedung itu sendiri. Bandara Internasional Juanda Surabaya memiliki gedung yang dilengkapi dengan sistem distribusi air pemadam kebakaran yang terkomputerisasi. Sehubungan dengan kejadian kebakaran di Bandara Juanda sendiri di salah satu bagian restoran pada akhir Desember 2007 maka perlu untuk dilakukan perencanaan ulang pada sistemnya. Perancangan sistem distribusi air pemadam kebakaran yang dilakukan meliputi penaksiran kebutuhan kapasitas air pemadam kebakaran penentuan diameter pipa air pemadam kebakaran perhitungan dan pemilihan pompa pemadam yang sesuai pemodelan dan simulasi dengan Software Pipe Flow Expert dan Software PyroSim serta review existing condition. Standar yang digunakan adalah NFPA untuk kebutuhan sprinkler dengan kapasitas 13 gpm dan tekanan 05 bar sedangkan untuk hydrant box dengan kapasitas 100 gpm dan tekanan 45 bar sementara itu Standar Hydraulic Institute Data dan Cameron Hydraulic Data adalah digunakan untuk properties instalasi. Hasil perancangan didapatkan untuk kebutuhan kapasitas air pemadam apabila kebakaran sampai 2 ruang yang terbakar adalah sebesar 356 gpm dan apabila kebakaran meluas sampai 10 ruang dalam waktu 15 menit adalah dibutuhkan kapasitas air pemadam sebesar 2070 gpm. Pompa pemadam adalah jenis sentrifugal dengan kapasitas 2 m3min dan head 5851 m dipilih merek EBARA dengan seri 150 MS 2537 sebanyak 4 pompa yang dioperasikan secara paralel sedangkan pompa joki adalah juga jenis sentrifugal dengan kapasitas 01 m3min dan head 5851 m dipilih seri EVM 419F sebanyak 1 pompa dan pompa booster adalah juga jenis sentrifugal dengan kapasitas 538984 lmin dan head 3511 m dipilih seri 200x150 CNHA 55 sebanyak 2 pompa yang dioperasikan secara paralel.


ABSTRACT

Fire water distribution system is one part of the important thing in the building installation. Design of this system is done with the correct calculation as according to structure design and also the function of itself building. Juanda International Airport Surabaya has the building provided with the fire water distribution system computerized. Refering to fire occurence in Juanda Airport in one part of its restaurant in the end of December 2007 hence need to be done by a redesign at their system. Design of fire water distribution system was done by covering of estimating of capacities requirement of fire water determining of diameter of fire water pipe calculating and selecting the appropriate fire pump modelling and simulating by Pipe Flow Expert Software and Pyrosim Software and also review existing condition. The standard was used in this design is NFPA Standard for the requirement of sprinkler with the capacities of 13 gpm and the pressure of 05 bar while for the hydrant box with the capacities of 100 gpm and the pressure of 45 bar meanwhile The Standard of Hydraulic Institute of Data and Cameron Hydraulic Data was used for the properties of installation. The result of this design for the requirement of fire water capacities if fire until 2 spaces burned was equal to 356 gpm and if fire extend until 10 spaces during 15 minute was required the fire water capacities equal to 2070 gpm. The fire pump was centrifugal type with the capacities of 2 m3min and the head of 5851 m selected the brand of EBARA with the series of 150MS2537 as much 4 pumps operated parallelly while the jockey pump was also centrifugal type with the capacities of 01 m3min and the head of 5851 m selected with the series of EVM419F as much 1 pump and the booster pump was also centrifugal type with the capacities of 538984 lmin and the head of 3511 m with the series of 200x150CNHA55 as much 2 pump operated parallelly



Keywordspemadam kebakaran;kapasitas aliran;head pompa;pompa pemadam
 
Subject:  Distribusi air;Mobil pemadam kebakaran
Contributor
  1. Prof. Dr. Ir. I Made Arya Djoni, MSc
Date Create: 06/05/2010
Type: Text
Format: pdf.
Language: Indonesian
Identifier: ITS-Undergraduate-3100010037816
Collection ID: 3100010037816
Call Number: RSM 628.926 2 Mau p


Source
Undergraduate Theses,Mechanical Engineering,RSM RSM 628.926 2 Mau p, 2009

Coverage
ITS Community Only

Rights
Copyright @2009 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-9635-2105109605-Abstract_id.pdf - 9 KB
  2.  ITS-Undergraduate-9635-2105109605-Abstract_en.pdf - 9 KB
  3.  ITS-Undergraduate-9635-2105109605-Conclusion.pdf - 71 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.224.214.251
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2016 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan