EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya


Kampus ITS Sukolilo - Surabaya 60111

Phone : 031-5921733 , 5923623
Fax : 031-5937774
E-mail : libits@its.ac.id
Website : http://library.its.ac.id

Support (Customer Service) :
timit_perpus@its.ac.id








Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Taufik Rachmanu


Moh. Fandika Aqsa


Tondo Indra Nyata


Ansi Aflacha Putri


Aprillia Tri Wulansari


Dewi Eka Agustina




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely
Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

Still Confuse?
Please read our User Guide

Keyword
Mode
Expanded Search (for Free text search only)
 
OR You May Search Our Knowledges Using Google Customize Search :

Custom Search

ITS » Undergraduate Theses » Teknik Kes &Keselaman Kerja - D4
Posted by ansi@its.ac.id at 23/05/2011 11:36:25  •  1216 Views


PERANCANGAN DELUGE SYSTEM SPRINKLER MENGGUNAKAN SMOKE DETECTOR PADA GEDUNG DIREKTORAT PPNS-ITS

DESIGN OF DELUGE SYSTEM SPRINKLER USING THE SMOKE DETECTOR IN THE BUILDING DIRECTORATE PPNS-ITS.

Created by :
UMBORA, RICKI PAULUS  ( 6506040025 )



Subjectkebakaran
sistem pemadaman
Alt. Subject Fire sprinklers
Keywordsmoke detector
deluge system sprinkler
water need.

Description:

Bahaya kebakaran yang berpotensi timbul pada gedung direktorat PPNS-ITS diklasifikasikan sebagai bahaya kebakaran ringan. Sprinkler sistem “Deluge” menggunakan sistem detektor asap yang diaplikasikan pada sistem penanggulangan kebakaran pada Gedung Direktorat PPNS-ITS. Dirancang menurut SNI 03-3985-2000 tentang tata cara perencanaan, pemasangan dan pengujian sistem deteksi dan alarm kebakaran untuk pencegahan bahaya kebakaran pada bangunan rumah dan gedung, SNI 03-3989-2000 tentang tata cara perencanaan dan pemasangan sprinkler otomatik untuk pencegahan bahaya kebakaran pada bangunan rumah dan gedung, dan SNI 03-1745-2000 tentang tata cara perencanaan dan pemasangan sistem pipa tegak untuk pencegahan bahaya kebakaran pada bangunan rumah dan gedung. Sprinkler sistem “Deluge” dirancang di setiap ruangan, katup Deluge yang digunakan adalah model F. Sistem deteksi dan alarm akan dihubungkan dengan air sebagai media pemadam. Material sistem perpipaan adalah galvanis, ukuran diameter pipa adalah 4” untuk pipa utama, 2,5” untuk pipa pembagi, 1” untuk pipa cabang. Dari perhitungan jumlah detektor yang dibutuhkan lantai 1 adalah 26 detektor, lantai 2 adalah 18 detektor , dan lantai 3 adalah 18 detektor, Sedangkan untuk perhitungan sprinkler yang dibutuhkan lantai 1 adalah 82 sprinkler, lantai 2 adalah 71 sprinkler , dan lantai 3 adalah 71 sprinkler, kebutuhan air 6240 liter/menit. Sedangkan daya tampung untuk 3 bak air masing-masing adalah 2250 liter . Kapasitas pompa 19,6 hp atau 18,2 kw.


Alt. Description

Potential fire hazards that arise in directorate building of PPNS-ITS classified as light a fire hazard. Deluge system Sprinkler using smoke detector that was applied to the fire protection system at the Directorate Building of PPNS-ITS. Designed by SNI 03-3985-2000 about the way of planning, installation and testing of detection and fire alarm systems for fire protection in houses and buildings, SNI 03-3989-2000 on procedures for planning and installation of automatic sprinklers for fire protection on buildings and houses, and SNI 03- 1745-2000 on procedures for planning and installation of vertical pipe system for fire protection in buildings and houses. Deluge system Sprinkler is designed in every room, deluge valve that is used is the model F. Detection and alarm systems will be connected with water as extinguishing media. Piping system material is galvanized, the piping diameter is " for branches pipe. From calculate detector needed to first floor is 26 detectors, second floor is 18 detectors, third floor is 18 detectors. Whereas calculation for sprinkler needed of the first floor is 82 sprinkler, second floors is 71 sprinkler, and the third floor is 71 sprinkler, Water requirement 6240 lit/min, Whereas Capacity for 3 reservoir each is 2250 liter, Capacity of power pump 19,6 hp or 18,2 kw.

Contributor:
  1. EKO JULIANTO, Ir., M.Sc.
  2. PRIYO AGUS S., ST.
Date Create:24/09/2010
Type:Text
Format:pdf
Language:Indonesian
Identifier:ITS-Undergraduate-3100011041761
Collection ID:3100011041761
Call Number:RSPP 628.925 2 Umb p


Source :
Undergraduate Thesis, Occupational Safety and Health Engineering, RSPP 628.925 2 Umb p, 2010

Coverage :
ITS Community

Rights :
Copyright @2010 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library


Publication URL :
http://digilib.its.ac.id/perancangan-deluge-system-sprinkler-menggunakan-smoke-detector-pada-gedung-direktorat-ppnsits-14569.html




[ Free Download - Free for All ]

  1.  ITS-Undergraduate-14569-Cover_idpdf.pdf - 22 KB
  2.  ITS-Undergraduate-14569-Cover_enpdf.pdf - 95 KB
  3.  ITS-Undergraduate-14569-Approval_Sheetpdf.pdf - 163 KB
  4.  ITS-Undergraduate-14569-Abstract_idpdf.pdf - 163 KB
  5.  ITS-Undergraduate-14569-Abstract_enpdf.pdf - 163 KB
  6.  ITS-Undergraduate-14569-Table_of_Contentpdf.pdf - 178 KB
  7.  ITS-Undergraduate-14569-Illustrationspdf.pdf - 286 KB
  8.  ITS-Undergraduate-14569-Tablespdf.pdf - 279 KB
  9.  ITS-Undergraduate-14569-Chapter1pdf.pdf - 321 KB
  10.  ITS-Undergraduate-14569-Conclusionpdf.pdf - 286 KB
  11.  ITS-Undergraduate-14569-Bibliographypdf.pdf - 283 KB
  12.  ITS-Undergraduate-14569-Presentation-pdf.pdf - 665 KB
  13.  ITS-Undergraduate-14569-Enclosure_Listpdf.pdf - 269 KB

[ FullText Content - Please, register first ]

  1. ITS-Undergraduate-14569-Chapter2pdf.pdf - 724 KB
  2. ITS-Undergraduate-14569-Chapter3pdf.pdf - 345 KB
  3. ITS-Undergraduate-14569-Chapter4pdf.pdf - 1070 KB
  4. ITS-Undergraduate-14569-Enclosure1pdf.pdf - 972 KB
  5. ITS-Undergraduate-14569-Enclosurepdf.pdf - 210 KB



Give your Comment here...


 10 Similar Document...

     No similar subject found !

 10 Related Document...






HELP US !
You can help us to define the exact keyword for this document by clicking the link below :

deluge , deluge system sprinkler , detector , need. , smoke , smoke detector , sprinkler , system , water , water need.



POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan




53560997


Visitors Today : 1
Total Visitor : 2515801

Hits Today : 10608
Total Hits : 53560997

Visitors Online: 1


Calculated since
16 May 2012

You are connected from 10.199.13.5
using CCBot/2.0 (http://commoncrawl.org/faq/)


ITS Digital Repository Feeds



Copyright © ITS Library 2006 - 2014 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan