RANCANG BANGUN RANGKAIAN PENYAERAH GELOMBANG PENUH TAK TERKONTROL TIGA FASA DENGAN HARMONISA RENDAH

CIRCUIT AC TO DC FULL CONVERTER UNCONTROLLED THREE FASE WITH LOW HARMONICS

Author :
ABDILLAH, MOCHAMAD ( 7306040012 )




ABSTRAK

Proyek akhir ini mengerjakan suatu rangkaian ac to dc full converter tiga fasa tak terkontrol harmonisa rendah dengan mendesain filter. Dimana mula-mula sebelum dipasang filter pasif maka beban AC to DC Full Converter tiga fasa ini menghasilkan harmonisa frekuensi ke-3 dengan nilai yang cukup kecil frekuensi ke 5 7 11. Hal ini sesuai dengan teori bahwa untuk konverter enam pulsa maka harmonisa yang muncul sesuai dengan rumus 6n1. Sehingga kemungkinan yang muncul adalah frekuensi 5711 dst. Namun nilai yang tinggi diantara harmonisa-harmonisa tersebut adalah frekuensi ke-5 kemudian ke-7 sedangkan frekuensi ke-3 dan ke-11 kecil sekali dalam batas toleransi yang diijinkan sehingga filter pasif untuk tujuan agar rangkaian yang dibuat ini harmonisanya rendah adalah didisain untuk membuang frekuensi ke-5 dan ke-7 kemudian rangkaian ini dibebani motor dc 100volt dc.


ABSTRACT

This final project is working on AC to DC Full Converter Uncontrolled Three Phase with low harmonic filter design. Where at first before the passive filters is installed into AC to DC Full Converter Uncontrolled Three Phase it produced the 3rd harmonic frequency with a small enough value and the 5th harmonic frequency and 7th with significant value that must be eliminated. This is like as theory that for the six pulse converter the harmonics will appearis in numbered with the formula 6n1. Of course it will appear the frequency 5th 7th 11th. However the high value of harmonic frequency are the 5th then the 7th while the frequency of the 3rd and the 11 small within the allowable tolerance limits. So the passive filter is designed to eliminate the 5th and 7th frequency then this circuit loaded dc motor 100 volt dc. From the test we get data that the 5th frequency previously have value 1941 then decrease in value 798 and the 7th frequency previously have value 078 then decrease to be 008. So the THD reduced about 75.



Keywordsmodel standar ; teori
 
Subject:  Arus listrik konverter
Contributor
  1. Endro Wahjono,SST,MT.
  2. Ir.Hendik Eko H.S., MT.
Date Create: 23/02/2011
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-3100011042466
Collection ID: 3100011042466
Call Number: RSEP 621.313 Abd r


Source
Undergraduate Thesis, Industrial Electronic, RSEP 621.313 Abd r, 2011

Coverage
ITS Community

Rights
Copyright @2011 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-15113-Abstract_id-pdf.pdf - 178 KB
  2.  ITS-Undergraduate-15113-Abstract_en-pdf.pdf - 179 KB
  3.  ITS-Undergraduate-15113-Conclusion-pdf.pdf - 178 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 18.207.106.142
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2020 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan