ANALISA BEBAN PENDINGINAN AKIBAT KONVEKSI DAN RADIASI PADA REEFERCONTAINER YANG BEKERJA SEBAGAI CHILLER DAN REFRIGERATOR

COOLING LOAD ANALYSIS DUE TO HEAT CONVECTION AND RADIATION ON REEFER CONTAINER ON CHILLER AND REFRIGERATION MODE

Author :
PARAMITA, ASTRID LIDYA  ( 2103109011 )




ABSTRAK

Container petikemas adalah suatu kemasan yang dirancang secara khusus dengan ukuran tertentu untuk dapat digunakan berulangkali digunakan untuk menyimpan dan sekaligus mengangkut muatan didalamnya. Dengan menggunakan petikemas yang terstandar muatan dapat dipindahkan dari berbagai moda transportasi laut dan darat dengan mudah sehingga dapat dioperasikandengan efisien cepat dan aman. Reefer container petikemas berpendingin adalah salah satu jenis container yang digunakan untuk menjaga kesegaran komoditas dalam transportasinya melalui moda transportasi laut baik dalam pelayaran domestik maupun manca negara. Pada saat reefer container akan digunakan maka ruangan pendingin dikondisikan dalam temperatur yang diset setting temperature sesuai persyaratan temperatur yang diperlukan oleh komoditas yang akan ditransportasikan. Selanjutnya komoditas tersebut dipindahkan ke dalam ruang pendingin reefer container dalam keadaan temperatur telah memenuhi persyaratan temperatur yang diperlukan dan kemudian reefer container ditutup rapat dan dijaga temperaturnya dalam kondisi tetap sama. Penelitian ini menganalisis beban pendinginan yang terjadi akibat konveksi dan radiasi pada reefer container yang berisi komoditas berupa daging dan buah yang telah berada pada temperatur pendinginan setting temperature yang dipersyaratkan oleh masing-masing komoditas tersebut. Perhitungan beban pendinginan ini dilakukan dengan mempertimbangkan pengaruh panas matahari yang bekerja pada reefer container melalui atap dinding pintu dan lantai dengan konstruksi masing-masing yang berbeda. Selanjutnya dalam perhitungan pengaruh pemanasan secara konveksi dan radiasi karena pemanasan matahari dipertimbangkan pengaruh aliran udara yang bekerja apabila reefer container berada pada kapal yang sedang berlayar dan pada berbagai posisi matahari. Dari penelitian ini diketahui besarnya tambahan beban pendinginan yang diakibatkan oleh pemanasan secara konveksi dan radiasi untuk kerja reefer container sebagai chiller sebesar 6.4163 Watt dan sebagai refrigerator sebesar 40725 Watt.


ABSTRACT

A Container is a specially designed storage room with standardized size and reusable to store as well as transport cargoesgoods. By using standardized dimensions container loads may be transported with ease through means of land and sea transportation hence efficient fast and safe operational.Reefer Containers refers to a speciallized container that is used to keep its load lifetime longer for sea transportation through its refrigerant system. For operation Reefer Containers are set beforehand to adjust its inner temperature for the type of cargo commodity that it will carry. Next the commodity may be moved inside the container with the inner temperature already set to be transported while the temperature is kept. This research analyze the cooling load that results from radiation and convection on the reefer container filled with meat and fruits due to external factors while already on the setting temperature required by each type of commodity.Calculations are made by factoring the effect of heat on the reefer container through its roof door and wall which is constructed differently from each other. Next in the calculation of the effect of convection and radiation doe to the solar heat we also take the effect of air flow on a sailing ship Through this research we know the amount of additional cooling load that has to be supplied due to radiation andconvection of heat while the reefer container is acting as chiller which is 64163 Watt and as refrigerator which is 40725 Watt.



KeywordsReefer container; Beban pendinginan akibat konveksi dan radiasi
 
Subject:  Mesin pendingin
Contributor
  1. Dr. Ir. Prabowo, M.Eng
Date Create: 17/02/2011
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-3100011043429
Collection ID: 3100011043429
Call Number: RSM 621.56 Par a


Source
Undergraduate Thesis of Mechanical Engineering, RSM 621.56 Par a, 2011

Coverage
ITS Community

Rights
Copyright @2011 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-16481-Abstract_id.pdf - 390 KB
  2.  ITS-Undergraduate-16481-Abstract_en.pdf - 220 KB
  3.  ITS-Undergraduate-16481-2103109011-Conclusion.pdf - 215 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.198.54.142
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan