 |
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya
Kampus ITS Sukolilo - Surabaya 60111
|
|
Phone |
: |
031-5921733 , 5923623 |
|
Fax |
: |
031-5937774 |
|
E-mail |
: |
libits@its.ac.id |
|
Website |
: |
http://library.its.ac.id
|
Support (Customer Service) :
|
|
timit_perpus@its.ac.id |
|
|
Welcome..guys!
|
Have a problem with your access?
Please, contact our technical support below:
|
LIVE SUPPORT
 Taufik Rachmanu  Dewi Eka Agustina  Ansi Aflacha Putri  Tondo Indra Nyata  Aprillia Tri Wulansari
|
! ATTENTION !
To facilitate the activation process, please fill out the member application form correctly and completely
Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently
Still Confuse?
Please read our User Guide
|
|
ITS » Undergraduate Theses » Teknik Fisika Ekstensi S1 Posted by zamrud@its.ac.id at 29/12/2011 09:27:22 • 294 Views
PERANCANGAN SISTEM PENGENDALIAN TEMPERATURE PADA REBOILER METANOL RECOVERY MENGGUNAKAN FUZZY GAIN SCHEDULING-PID DI PT. ETERINDO NUSA GRAHA GRESIKDESIGNING TEMPERATURE CONTROL
SYSTEM IN REBOILER METHANOL RECOVERY
USING FUZZY GAIN SCHEDULING - PID
AT PT. ETERINDO NUSA GRAHA GRESIKCreated by :
FIRMANTO, AGUS HANDRIAN ( 2409105036 )
| Subject: | Kontrol teori | | Alt. Subject : | PID controllers Fuzzy logic | | Keyword: | Temperature Reboiler Fuzzy Gain Scheduling -
PID |
Description:
Distillation Column merupakan proses pemisahan yang paling banyak digunakan dan salah satu komponennya adalah reboiler. Distillation Column memisahkan suatu komponen campuran berdasarkan komposisi dari cairan dan uap dari bentuk awal yang berupa cairan. Suhu pada reboiler perlu dikendalikan untuk menjaga kestabilan suhu keluaran metanol sehinggga tingkat kemurnian yang diinginkan dapat diperoleh. Untuk mendapatkan harga tuning Kp, Ki dan Kd dilakukan dengan metode T-L osilasi dan didapatkan nilai Kp = 13.4, Ki = 0.3 dan Kd = 49.2. Menggunakan pengendali Fuzzy Gain Scheduling -
PID didapatkan karakteristik respon keluaran yang lebih baik dibandingkan dengan pengendali PID. Untuk pengendali PID didapatkan nilai maximum overshoot = 18,88 %, settling time = 74 detik. Sedangkan untuk Fuzzy Gain Scheduling - PID didapatkan nilai Maximum vershoot = 0 %, settling time = 34 detik.
Alt. Description
A distillation column is a separation process that is most used and one of its components is reboiler. Distillation column work based on separation the mixture to the vapor and liquid from its original form in liquid. Temperature on deaerator need to be controlled in order to maintain temperature output stability then get the purity level that wanted. To obtain Kp, Ki and Kd value, T-L ocillation method was used and obtained Kp = 13.4, Ki = 0.3 also Kd = 49.2. Fuzzy Gain Scheduling – PID has better response than PID controller. For PID controller was obtained, maximum overshoot = 18,88 %, settling time = 74 second. Meanwhile for Fuzzy Gain Scheduling – PID controller was obtained, maximum overshoot = 0 %, settling time = 34 second
| Contributor | : |
- Ir. Syamsul Arifin, MT
- Ir. Roekmono
| | Date Create | : | 09/08/2011 | | Type | : | Text | | Format | : | pdf | | Language | : | Indonesian | | Identifier | : | ITS-Undergraduate-3100011044445 | | Collection ID | : | 3100011044445 | | Call Number | : | RSF 629.89 Fer p |
Source : Undergraduate Thesis of Physics Engineering, RSF 629.89 Fer p, 2011
Coverage : ITS Community
Rights : Copyright @2011 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library
Publication URL : http://digilib.its.ac.id/perancangan-sistem-pengendalian-temperature-pada-reboiler-metanol-recovery-menggunakan-fuzzy-gain-schedulingpid-di-pt-eterindo-nusa-graha-gresik-16956.html
[ Free Download - Free for All ]
ITS-Undergraduate-16956-perancangan-sistem-pengendalian-temperature-pada-reboiler-metanol-recovery-menggunakan-fuzzy-gain-sc.pdf - 41 KB ITS-Undergraduate-16956-designing-temperature-controlsystem-in-reboiler-methanol-recoveryusing-fuzzy-gain-scheduling-pidat-p.pdf - 28 KB ITS-Undergraduate-16956-Approval_Sheet.pdf - 315 KB ITS-Undergraduate-16956-Abstract_id.pdf - 177 KB ITS-Undergraduate-16956-Abstract_en.pdf - 174 KB ITS-Undergraduate-16956-Preface.pdf - 182 KB ITS-Undergraduate-16956-Table_of_Content.pdf - 202 KB ITS-Undergraduate-16956-Tables.pdf - 525 KB ITS-Undergraduate-16956-Illustrations.pdf - 201 KB ITS-Undergraduate-16956-Notations.pdf - 194 KB ITS-Undergraduate-16956-Bibliography.pdf - 176 KB ITS-Undergraduate-16956-Biography.pdf - 360 KB ITS-Undergraduate-16956-Chapter1-222343.pdf - 217 KB ITS-Undergraduate-16956-Conclusion-192618.pdf - 188 KB ITS-Undergraduate-16956-Paper-651146.pdf - 636 KB ITS-Undergraduate-16956-Presentation-2358832.pdf - 2304 KB
[ FullText Content - Please, register first ]
1. ITS-Undergraduate-16956-Chapter2-348247.pdf - 340 KB 2. ITS-Undergraduate-16956-Chapter3-632194.pdf - 617 KB 3. ITS-Undergraduate-16956-Chapter4-806418.pdf - 788 KB 4. ITS-Undergraduate-16956-Enclosure-673784.pdf - 658 KB
Give your Comment here...
10 Similar Document...
No similar subject found !
10 Related Document...
|
POLLINGBagaimana pendapat Anda tentang layanan repository kami ?

      
Visitors Today : 2834
Total Visitor : 1430130
Hits Today : 58447
Total Hits : 24012483
Visitors Online: 91
Calculated since 16 May 2012
You are connected from 107.21.186.38 using CCBot/2.0
|