PERANCANGAN SISTEM PENGENDALIAN LEVEL DAN INTERLOCK STEAM DRUM DENGAN DUA ELEMEN KONTROL DI PT. INDONESIA POWER UBP SUB UNIT PERAK

CONTROL SYSTEM AND INTERLOCK STEAM DRUM LEVEL DESIGN USING TWO CONTROL ELEMENTS AT PT.INDONESIA POWER UBP SUB UNIT PERAK

Author :
ABDURRAHMAN, WAHID ( 2409105006 )




ABSTRAK

Pada dasarnya proses pembangkitan listrik terdiri dari beberapa bagian antara lain proses pada desalination penyaringan air laut menjadi air tawar boiler turbin pembangkitan listrik di generatordll. Salah satu yang paling utama dan penting adalah proses pada steam drum. Pada Steam drum apabila level terlalu rendah akan timbul kerusakan pada steam drum dan apabila level terlalu tinggi maka akan berbahaya karena akan membuat sistem yang bekerja menjadi shutdown.Maka dari itu diperlukan suatu sistem pengendalian untuk menjaga level dari steam drum tersebutsalah satunya dengan sistem pengendalian level mode kontrol PID.Penentuan parameter kontrol PID yang dilakukan adalah dengan Ziegler-Nichols.Dari hasil pengujian dan analisa sistem pengendalian level dan interlock.Dengan menggunakan metode ziegler-nichols diperoleh nilai Kp2172Ti1105danTd027625.kemudian didapatkan bahwa respon sistem pengendalian level dan interlock stabil dengan settling time 147 smaksimum overshootnya yaitu sebesar 286 rise time Tr 10 s Peak time Tp 45 sdan delay time 27 s.


ABSTRACT

Basically the process of electricity generation consists of several parts including the desalination process filtering sea water into fresh water boiler turbine generating electricity in generators etc.. One of the foremost and most important is the process in the steam drum. In the steam drum when the level is too low there will be damage to the steam drum and if the level is too high then it would be dangerous because it will make the system work to be shutdown.Than that required of a control system to maintain the level of the steam drum one with the control system PID.Level mode PID control parameters is carried out by Ziegler-Nichols.From test results and analysis of the level control system and interlock.using Ziegler-Nichols method Kp values obtained 21.72 Ti 1.105 danTd 0 27625. found that the response level and interlock control system is stable with the settling time 147 s the maximum overshootnya that is equal to 28.6 rise time Tr 10 s peak time Tp 45 s and delay time 27 s



KeywordsSteam Drum;Level;Ziegler-Nichols
 
Subject:  Uap
Contributor
  1. Hendra Cordova, ST, MT
  2. Dyah Sawitri, ST, MT
Date Create: 12/08/2011
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-3100012045539
Collection ID: 3100012045539
Call Number: RSF 621.183 Abd p


Source
Undergraduate Thesis, Physics Engineering, RSF 621.183 Abd p, 2011

Coverage
ITS Community

Rights
Copyright @2012 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-17957-Abstract_id-pdf.pdf - 156 KB
  2.  ITS-Undergraduate-17957-Abstract_en-pdf.pdf - 179 KB
  3.  ITS-Undergraduate-17957-Conclusion-pdf.pdf - 80 KB
  4.  ITS-Undergraduate-17957-Paperpdf.pdf - 417 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.81.59.211
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan