EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya


Kampus ITS Sukolilo - Surabaya 60111

Phone : 031-5921733 , 5923623
Fax : 031-5937774
E-mail : libits@its.ac.id
Website : http://library.its.ac.id

Support (Customer Service) :
timit_perpus@its.ac.id




Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Moh. Fandika Aqsa


Davi Wahyuni


Tondo Indra Nyata


Anis Wulandari


Ansi Aflacha




ITS » Undergraduate Theses » Teknik Kes & Keselamatan Kerja
Posted by dee@its.ac.id at 27/07/2012 15:33:23  •  2787 Views


PERANCANGAN TEMPAT PENYIMPANAN SEMENTARA BAHAN KIMIA BERACUN DAN BERBAHAYA DI PT. MERMAID TEXTILE INDUSTRI INDONESIA PT. MERTEX

TEMPORARY STORAGE OF HAZARDOUS AND TOXICAL CHEMICAL SUBSTANCES DESIGNED AT PT. MERMAID TEXTILE INDUSTRIES INDONESIA PT. MERTEX

Author :
NUR, SAADILLAH IHDIAR  ( 6507040005 )




ABSTRAK

PT. MERTEX merupakan perusahaan yang memproduksi kain atau barang textil. PT. MERTEX belum memiliki tempat penyimpanan sementara bahan kimia berbahaya yang seuai dengan kondisi jumlah bahan kimia sehingga peletakan bahan kimia diletakkan pada tempat-tempat yang tidak semestinya digunakan sebagai tempat penyimpanan sementara. Untuk mengatasi masalah tersebut dalam penelitian ini akan dirancang tempat penyimpanan bahan kimia beracun dan berbahaya di perusahaan ini. Perancangan ini disesuaikan dengan standart perancangan tempat penyimpanan sementara bahan kimia di industri. Perancangan diawali dengan melakukan penggolongan bahan kimia berdasarkan kompatibilitas dengan menggunakan software CRW . Setelah itu merancang kelengkapan bangunan seperti ventilasi proteksi penyalur petir dan pelabelan bahan kimia. Dari hasil pengklasifikasian dengan menggunakan software CRW tempat penyimpanan bahan kimia dibagi menjadi 6 ruangan dengan total luasan bangunan sebesar 7.059.600 cm2. Sistem ventilasi membutuhkan exhaust fan dengan tipe APW-54 yang memiliki kecepatan 60000 ft3min sebanyak 17 buah untuk total semua ruangan. Proteksi penyalur petir membutuhkan penerima petir sebanyak 7 buah 14 hantaran penurunan dan elektrode pembumian jenis batang sebanyak 4 buah. Menentukan simbol dan pelabelan ke 20 bahan kimia dengan melihat pada MSDS yang ada simbol dan pelabelan bahan kimia didasarkan pada Peraturan Menteri Negara Lingkungan Hidup No. 3MEN 2008.


ABSTRACT

PT. MERTEX is a company which manufactures fabric or textile goods. PT. MERTEX havent a place in accordance with the chemical quantity condition consequently that chemical subtances put in a places that not be used as a chemical storage. So that needs to be designed a temporary storage chemical place. To solve the problem in this research will be designed a toxic and hazardous chemicals storge at this company.The design was adapted from design standart of the industrial chemical storage. Designing start from to classified chemical compatibility with CRW software. After that designed the building complements such as industrial vents lightning protection instalation and chemical labeling. Based on the chemical classification using CRW software the chemical storage divided into 6 rooms with the total building area is 7.059.600 cm2. The ventilation system needs 17 pieces exhaust fan APW-54 type which is have a speed of 60 000 ft3min for a total rooms. The lightning protection instalation require 7 pieces air terminal 14 pieces down conductor and 4 pieces rod type grounding electrode.



KeywordsCRW classification; Industrial ventilation; Lightning protection dealers; Symbols; Hazardous chemical labeling
 
Subject:  Arsitektur kapal
Contributor
  1. Rona Riantini, ST., M.Sc.
  2. Denny Dermawan, ST., MT.
Date Create: 29/07/2011
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-3100012046896
Collection ID: 3100012046896
Call Number: RSKe 623.812 Akb s


Source
Undergraduate Thesis of Occupational Safety and Health Engineering, RSKe 623.812 Akb s, 2012

Coverage
ITS Community

Rights
Copyright @2011 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-20254-6507040005-Abstract_id.pdf - 175 KB
  2.  ITS-Undergraduate-20254-6507040005-Abstract_en.pdf - 209 KB
  3.  ITS-Undergraduate-20254-6507040005-Conclusion.pdf - 217 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 35.175.248.25
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2019 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan