EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya


Kampus ITS Sukolilo - Surabaya 60111

Phone : 031-5921733 , 5923623
Fax : 031-5937774
E-mail : libits@its.ac.id
Website : http://library.its.ac.id

Support (Customer Service) :
timit_perpus@its.ac.id




Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Moh. Fandika Aqsa


Davi Wahyuni


Tondo Indra Nyata


Anis Wulandari


Ansi Aflacha




ITS » Paper and Presentation » S1 - Teknik Mesin Lintas Jalur
Posted by dee@its.ac.id at 22/12/2014 22:24:47  •  1183 Views


STUDI EKSPERIMEN PENGARUH VARIASI KECEPATAN UDARA TERHADAP PERFORMA HEAT EXCHANGER JENIS COMPACT HEAT EXCHANGER RADIATOR DENGAN SUSUNAN TUBE INLINE SEBAGAI PEMANAS PADA SISTEM PENGERINGAN BATUBARA

EXPERIMENTAL STUDY OF AIR SPEED VARIATION WITH TUBE COMPOSED INLINE TO COMPACT HEAT EXCHANGER RADIATOR PERFORMANCE AS AIR HEATER IN DRYING COAL SYSTEM

Author :
PARAMANANDA, IRVAN ( 2111105005 )




ABSTRAK

Di Indonesia masih banyak batubara yang tergolong dalam batubara kalor rendah. Saat ini sudah banyak sekali dikembangkan teknologi untuk meningkatkan nilai kalor dari batubara yang semula tergolong batubara dengan nilai kalor rendah menjadi batubara dengan nilai kalor tinggi. Pengeringan yang dilakukan pada batu bara dengan memanfaatkan udara panas menggunakan konsep heat exchanger. Salah satu heat exchanger yang sering digunakan adalah heat exchanger dengan tipe single row-fin tube yaitu radiator. Radiator ini akan dimanfaatkan sebagai penghasil udara panas dari air panas yang mengalir dan dihembuskan oleh kipas radiator. Pada tugas akhir ini dilakukan penelitian dengan metode eksperimen pada suatu sistem pengeringan batubara. Sistem pengeringan batu bara yang diuji memiliki empat komponen utama yaitu radiator blower blade dan acryclic sebagai drying chamber. Penelitian ini difokuskan pada effectiveness dari komponen radiator fungsi dari kecepatan udara mulai dari kecepatan 1 ms 2 ms 3 ms 4 ms dan 5 ms dan fungsi jumlah radiator yang digunakan. Prinsip dari radiator yang digunakan adalah mengalirkan fluida panas berupa air ke dalam tube-tube radiator kemudian didinginkan oleh udara yang dihembuskan oleh fan yang melewati fin sehingga air yang keluar dari tube menjadi dingin dan udara yang melewati fin menjadi panas. Hasil yang didapatkan dari eksperimen ini diantaranya kecepatan udara yang optimal terhadap proses pengeringan batu bara yang dipakai pada alat pengering batu bara adalah sebesar 5 ms dengan menggunakan 2 radiator. qhot untuk penggunaan 2 radiator dengan kecepatan udara sebesar 5 ms adalah 30121.17 Watt. Effectiveness pada penggunaan 2 radiator dengan kecepatan udara sebesar 5 ms adalah 0.65. Efisiensi fin yang terjadi pada kecepatan udara 5 ms dengan menggunakan 2 radiator sebesar 0.93.


ABSTRACT

In Indonesia there are many of coal belonging to the low calorific coal. There is a lot of technologies developed to increase the calorific value of coal which was originally classified as a low calorific value coal into coal with high calorific value. Drying is done on coal with using a hot air with using the concept of heat exchanger. Heat exchangers are often used to single row-fin tube radiator. The radiator will be utilized to produce of hot air from flow of the hot water and exhaled by the radiator fan. In this thesis research with experimental methods in a coal drying system. Coal drying system to be tested has four components radiator blower blade and acryclic as a drying chamber. This study focused on the effectiveness of radiator components to air velocity with range of speeds are 1 ms 2 ms 3 ms 4 ms and 5 ms and the number of radiators used. The principle of the radiator flow fluid as hot water into the radiator tubes and then it cooled by air blown from the fan and passes the fin so the water from the tube become cold and the air passes the fins become hot. Results obtained from this experiment include optimum air velocity on the drying process of coal used in coal dryer is 5 ms by using 2 radiators. qhot to use 2 radiators with air velocity of 5 ms is 30121.17 Watt. Effectiveness in the use of two radiators with air velocity of 5 ms is 0.65. Fin efficiency that occurs at the air velocity of 5 ms by using 2 radiators of 0.93.



Keywordseffectiveness; kecepatan udara; compact heat exchanger; jumlah radiator; udara panas; efisiensi fin
 
Subject:  Termodinamika
Contributor
  1. Prof. DR. Eng. Ir. Prabowo, M.Eng.
Date Create: 01/01/2014
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-paper-21121140006009
Collection ID: 21121140006009
Call Number: RSM 621.402 5 Par s


Source
Paper and Presentation of Mechanical Engineering, RSM 621.402 5 Par s, 2014

Coverage
ITS Community

Rights
Copyright @2014 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-paper-34974-2111105005-paper.pdf - 506 KB
  2.  ITS-paper-34974-2111105005-presentation.pdf - 1766 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.80.26.116
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan