Posted by dee@its.ac.id at 22/12/2014 23:16:52  •  1058 Views


OPTIMALISASI GENERATOR GAS HHO TIPE WET CELL DIMENSI 160X160 MM 120X120 MM DENGAN PENAMBAHAN DIGITAL PULSE WIDTH MODULATION DAN NETRAL PLAT

OPTIMIZATION OF GAS GENERATOR HHO WET CELL TYPE DIMENSIONS 160X160 MM 120X120 MM WITH ADDITION OF DIGITAL PULSE WIDTH MODULATION AND NEUTRAL PLATE

Author :
SILAEN, CHANDRA ( 2111105014 )




ABSTRAK

Dari hasil penelitian mengenai generator gas HHO sebelumnya didapat bahwa panas yang ditimbulkan dari proses elektrolisa dapat mencapai temperatur 800C. Oleh permasalahan tersebut menyebabkan pemakaian arus dari accu untuk mensupply kebutuhan daya generator gas HHO menjadi besar dengan hasil produksi gas HHO yang kecil dan panas tinggi yang ditimbulkan akibat dari proses elektrolisa dapat merusak bejana generator gas HHO sehingga dapat menyebabkan kebocoran pada generator gas HHO. Bila dioperasikan dalam waktu yang cukup lama membuat pengguna generator gas HHO merasa tidak aman safety bila terjadi kebocoran pada bejana generator gas HHO. Dari permasalahan yang ada maka ditambahkan Digital Pulse Width Modulation PWM untuk mengatur arus yang digunakan pada proses elektrolisa dan menambahkan plat netral pada elektroda generator gas HHO tipe wet cell yang nantinya akan meningkatkan laju produksi gas HHO. Penelitian dilakukan di Laboratorium Teknik Pembakaran Dan Bahan Bakar Jurusan Teknik Mesin FTI-ITS dimana penelitian ini menggunakan generator gas HHO tipe wet cell menggunakan elektroda berbentuk plat berdimensi 160x160 mm dan 120x120 mm yang masing masing elektroda berjumlah 31 plat ss 316L yang tersusun dari 6 cell dimana tiap cellnya terdapat 4 plat netral dengan tebal plat 1.5 mm dan jarak antara plat dibatasi o-ring karet dengan tebal 2 mm. Larutan elektrolit yang digunakan untuk proses elektrolisa adalah campuran tiap 1 liter aquades dengan 2 gr KOH pengujian generator gas HHO tipe wet cell dilakukan selama 60 menit untuk menguji performa optimal dari generator gas HHO. Pengujian generator gas HHO dilakukan dengan 2 metode yaitu tanpa menggunakan PWM dan dengan menggunakan PWM pengujian menggunakan PWM dilakukan dengan variasi duty cycle 50 70 90 dan dengan frekuensi 1000 Hz dan 500 Hz untuk mengetahui performa optimal masing masing generator gas HHO tipe wet cell. Dari hasil penelitian ini didapatkan bahwa generator gas HHO dengan penambahan plat netral dapat menurunkan daya yang dibutuhkan untuk proses elektrolisa air serta meningkatkan laju produksi gas HHO. Dengan penambahan PWM daya yang dibutuhkan untuk generator gas HHO lebih dapat dikontrol laju produksi generator gas HHO dengan PWM lebih kecil dengan produksi gas HHO pada generator gas HHO tanpa PWM namun temperatur elektrolit dari generator gas HHO dengan PWM lebih rendah dari temperatur elektrolit generator gas HHO tanpa PWM. Pada 120x120mm dengan duty cycle 90 frekuensi 500 Hz didapat daya terbesar yaitu 264 watt laju produksi terbesar 6462x10-6 kgs dan efisiensi terbaik 5275 sedangkan pada 160x160mm dengan duty cycle 90 frekuensi 500 Hz didapat daya terbesar yaitu 264 watt laju produksi terbesar 6462x10-6 kgs dan efisiensi terbaik sebesar 4989 pada pengujian dengan duty cycle 90 dan frekuensi 1000 Hz.


ABSTRACT

From the results of research on HHO gas generators previously found that the heat generated from the electrolysis process temperatures can reach 800C. The problems caused by the use of current from the batteries to supply the power needs of HHO gas generators be great with HHO gas production is small and is caused by the high heat of the electrolysis process can damage the vessel so that the HHO gas generators can cause leaks in the gas HHO generator. When operated in quite a long time to make HHO gas generator users feel unsafe safety if there is a leak in the HHO gas generator vessel. Of the existing problems will be added to the Digital Pulse Width Modulation PWM to adjust the current used in the electrolysis process and add a neutral plate on the generator electrode type of wet cell HHO gas which will increase the rate of production of HHO gas. The experiments was conducted at the Laboratory of Combuction and Fuel Engineering Department of Mechanical Engineering FTI ITS which this experiment using wet cell type gas generator HHO using a plate shaped electrode dimensions 160x160 mm and 120x120 mm each electrode is 31 316L ss plate composed of 6 cell where each cell there are 4 neutral plates with plate thickness 0f 1.5 mm and the distance between the plates is limited by the rubber o-ring 2 mm thick. Electrolyte solution used for the electrolysis process is a mixture of 1 liter of distilled water each with 2 gr of KOH HHO gas generator testing wet cell type performed for 60 minutes to test the optimal performance of the HHO gas generator. HHO gas generator testing is done by two method without using PWM and using PWM the testing is done by using the PWM duty cycle variation of 50 70 90 and with a frequency of 1000 Hz and 500 Hz to determine the optimum performance of each gas generator HHO wet cell type. From the results of this experiments found that the addition of HHO gas generator neutral plates can reduce the power needed for water electrolysis process and increase the rate of production of HHO gas. With the addition of PWM power needed for more HHO gas generators can be controlled the rate of production of HHO gas generators with smaller PWM HHO gas production in the HHO gas generator without PWM but the temperature of the electrolyte with PWM HHO gas generator is lower than the temperature of the electrolyte HHO gas generators without PWM. At 120x120mm with a duty cycle of 90 frequency of 500 Hz obtained the largest power is 264 watts the largest production rate of 6.462 x10-6 kg s and the best efficiency of 52.75 while on 160x160mm with a duty cycle of 90 frequency of 500 Hz obtained the largest power is 264 watts the largest production



KeywordsHHO; Wet Cell; Duty Cycle; Frekuensi
 
Subject:  elektrolisis air
Contributor
  1. Prof. DR. Ir. H. D. Sungkono K, M. Eng.Sc
Date Create: 01/01/2014
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-paper-21121140006014
Collection ID: 21121140006014
Call Number: RSM 665.81 Sil o


Source
Paper and Presentation of Mechanical Engineering, RSM 665.81 Sil o, 2014

Coverage
ITS Community

Rights
Copyright @2014 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-paper-34989-2111105014-paper.pdf - 712 KB
  2.  ITS-paper-34989-2111105014-presentation.pdf - 1394 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.162.166.214
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan