Posted by dee@its.ac.id at 03/01/2013 09:52:09  •  1352 Views


PERBAIKAN KUALITAS ARUS PADA BUCK-BOOST INVERTER YANG TERHUBUNG GRID MENGGUNAKAN FEED-FORWARD COMPENSATION FFC

OUTPUT CURRENT QUALITY IMPROVEMENT OF GRID-CONNECTED BUCK-BOOST INVERTER USING FEED-FORWARD COMPENSATION FFC METHOD

Author :
NUGRAHANI, FARADISYAH ( 2208100182 )




ABSTRAK

Kualitas tegangan DC yang digunakan sebagai masukan inverter sering kali mengandung ripple dan mengalami fluktuasi. Tegangan DC tersebut bisa berasal tegangan generator AC yang disearahkan menggunakan rectifier. Ripple pada tegangan input inverter akan mempengaruhi kuliatas dari output inverter. Hal ini berlaku untuk kondisi inverter baik yang stand alone maupun yang terhubung grid. Oleh karena itu diperlukan metode untuk memperbaiki kualitas arus output inverter supaya sesuai dengan yang dibutuhkan jaringan. Pada Tugas Akhir ini akan dibahas perbaikan kualitas arus output dari buck-boost inverter yang terhubung grid. Metode yang digunakan adalah memanfaatkan deteksi ripple pada tegangan DC sumber yang dikombinasikan dengan sistem PWM pada inverter. Teknik ini disebut Feed-Forward Compensation FFC. Dari simulasi menunjukkan bahwa distorsi arus output pada buck-boost inverter dapat diturunkan ketika metode FFC diterapkan. Pemakain metode FFC pada tegangan input 400 Vdc dengan ripple 869 peak-to-peak dapat menurunkan THD arus mula sebesar 4778 menjadi 1324 . Sehingga dapat disimpulkan bahwa metode FFC efektif untuk meningkatkan arus keluaran dari buck-boost inverter.


ABSTRACT

DC voltage quality when used as input voltage of inverter often has ripples and fluctuated dramatically. DC input voltage derived from generator voltage which rectified using rectifier. The ripple in inverter input voltage will affect the quality of inverter output current. This applies in both stand alone and grid-connected conditions. Therefore it is required a method to improve the quality of inverter output current in order to be connected with grid. This final project will be studied about an improvement of quality output current from buck-boost inverters with grid-connected. The method used ripple detection in DC voltage source and combined with PWM system in inverter. This technique is called Feed-Forward Compensator FFC method. The simulation showed that the distortion of output current in buck-boost inverter can be derived when the FFC method is applied. Using FFC method on 400 Vdc with ripple 8.69 peak-to-peak can reduce THD current 4.778 to 1.324. So it can be concluded that FFC method is effective to improve the output current of the buck-boost inverter.



KeywordsRipple; Buck-boost inverter; FFC
 
Subject:  Listrik inverter
Contributor
  1. Dedet Candra Riawan ST, M.Eng, PhD
  2. Prof. DR. Ir. Mochamad Ashari, M.Eng.
Date Create: 13/07/2012
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-paper-22021120001648
Collection ID: 22021120001648
Call Number: RSE 621.381 532 2 Nug p


Source
Paper and Presentation of Electrical Engineering, RSE 621.381 532 2 Nug p, 2012

Coverage
ITS Community

Rights
Copyright @2012 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-paper-23052-2208100182-Paper.pdf - 597 KB
  2.  ITS-paper-23052-2208100182-Presentation.pdf - 1474 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 3.92.92.168
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2019 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan