ITS » Paper and Presentation » Arsitektur Lingkungan - S2
Posted by aprill@is.its.ac.id at 24/12/2013 13:10:36  •  1061 Views


KENYAMANAN TERMAL SISTEM PENGONDISIAN UDARA PADA APARTEMEN DENGAN VARIABEL LAYOUT POSISI SUPPLY DAN WINDOW WALL RATIO

THERMAL COMFORT OF AIR CONDITIONING SYSTEM IN APARTMENT WITH LAYOUT SUPPLY POSITION AND WINDOW WALL RATIO VARIABLES

Author :
SABTALISTIA, YUNITA ARDIANTI ( 3211204001 )




ABSTRAK

Kebutuhan konsumsi energi untuk sistem pengondisian udara air conditioning system semakin meningkat seiring dengan semakin meningkatnya kebutuhan udara bersih dan nyaman di dalam ruangan khususnya apartemen. Sistem FAC Floor Air Conditioning dan UFAC Under Floor Air Conditioning semakin berkembang karena lebih hemat energi daripada sistem CAC Ceiling Air Conditioning. Namun posisi supply AC yang ada di level bawah pada sistem FAC dan UFAC menyebabkan resiko terjadinya draft discomfort menjadi lebih besar karena supply AC lebih dekat dengan penghuni sehingga kenyamanan termal penghuni menjadi berkurang. Percampuran bahang dari jendela dinding luar dapur dan aktivitas penghuni di dalam tipe studio apartemen diduga mempengaruhi kenyamanan termal dalam ruangan. Penelitian ini bertujuan mengetahui kombinasi layout ruangan posisi supply AC dan WWR yang paling tinggi dari segi kenyamanan termal pada sistem CAC dan FAC di dalam hunian apartemen tipe studio. Hal itu dapat dilakukan dengan metode eksperimen untuk mengetahui perubahan layout ruangan posisi supply AC dan WWR terhadap kenyamanan termal dengan bantuan simulasi CFD Computational Fluid Dynamics. Hasil penelitian membuktikan sistem FAC lebih nyaman daripada CAC karena posisi supply AC menjauhi area berpenghuni dan sudut defleksi supply AC tidak mengarah langsung ke tubuh penghuni sehingga mengurangi terjadinya draft discomfort pada sistem FAC. Sistem FAC dengan layout 1 tempat tidur di depan jendela posisi supply AC di dinding dekat dapur dan nilai WWR sebesar 0.3 mempunyai kenyamanan termal yang tertinggi. Sistem CAC dengan layout 1 tempat tidur di depan jendela posisi supply AC di dinding kamar mandi dan nilai WWR sebesar 0.25 mempunyai kenyamanan termal terendah.


ABSTRACT

Energy consumption for air conditioning systems air conditioning system increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system Floor Air Conditioning and UFAC system Under Floor Air Conditioning is growing because there are more energy efficient than CAC system Ceiling Air Conditioning. However the position of the AC supply is on the lower level at the FAC system and UFAC causes draft discomfort risk becomes greater as AC supply closer to the occupants so that thermal comfort is be reduced. Heat mixture of windows exterior walls kitchen and occupants in the studio apartment affects thermal comfort in the room too. This study aims to determine the combination of the room layout the position of AC supply and WWR that has the highest of thermal comfort in the studio of apartment using the CAC and FAC system. This can be done by an experimental method to determine changes in room layout the position of AC supply and WWR on thermal comfort supported by CFD simulations Computational Fluid Dynamics simulation. The results prove the FAC system is more comfort than the CAC for AC supply position away from occupied areas and angle deflection of AC supply does not lead directly to the body of occupants thereby reducing the draft discomfort risk on the FACsystem. FAC system with layout1 the bed in front of the window AC supply position on the wall near the kitchen and WWR 03 has the highest thermal comfort. CAC system with layout1the bed in front of the window AC supply position on the bathroom wall and WWR 025 has the lowest thermal comfort.



KeywordsCeiling Air Conditioning (CAC); Draft; Floor Air Conditioning (FAC); Kenyamanan Termal; Window Wall Ratio (WWR)
 
Subject:  Apartemen rumah apartemen
Contributor
  1. Dr.Eng.Dipl Ing. Sri Nastiti N.Ekasiwi., M.T
  2. Dr.Ir. Bambang Iskandriawan.M.Eng
Date Create: 24/12/2013
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-paper-32021130003117
Collection ID: 32021130003117
Call Number: RTA 728.314 Sab k


Source
Paper and Presentation of Architecture, RTA 728.314 Sab k, 2013

Coverage
ITS Community

Rights
Copyright @2013 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-paper-28603-3211204001-Presentation.pdf - 1975 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.156.58.187
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan