Posted by dee@its.ac.id at 09/10/2013 09:39:52  •  1443 Views


ANALISIS SISTEM PROTEKSI PETIR EKSTERNAL DI OFFTAKE WARU PT. PERUSAHAAN GAS NEGARA PERSERO TBK SBU WIL II JABATI

ANALYSIS OF EXTERNAL LIGHTNING PROTECTION SYSTEM IN OFFTAKE WARU PT. PERUSAHAAN GAS NEGARA PERSERO TBK SBU WIL II JABATI

Author :
WALDY, MOHAMMAD ( 6408030009 )




ABSTRAK

Saat ini banyak perusahaan atau industri yang mengabaikan sistem proteksi petir. Intensitas curah hujan di Indonesia tergolong cukup tinggi membuat kemungkinan terjadi petir juga cukup besar. Pada penelitian ini dibahas tentang sistem proteksi petir eksternal yang berlokasi di Offtake Waru yang merupakan stasiun penerima gas. Sistem proteksi ini diperlukan karena lokasi tersebut berada diantara saluran pipa gas bertekanan tinggi yang mudah meledak mempunyai area yang cukup luas serta banyaknya pekerja. Metode yang digunakan pada peneilitian ini adalah metode checklist yang mengacu pada PUIL 2000 dan Permenaker No 02 MEN 1989. Metode checklist ini digunakan karena mudah dan detail sehingga dapat diketahui kondisi nyata yang ada di lapangan. Dalam penulisan field project ini diharapkan dapat memberikan informasi bahwa perlunya penerapan ketentuan sistem proteksi petir eksternal yang diakui. Dengan terpenuhinya ketentuan sistem proteksi petir eksternal di suatu lokasi kerja maka karyawan dapat merasa aman dan membuat hasil pekerjaan menjadi maksimal. Pemeliharaan dan perawatan juga harus dilakukan secara rutin pada sistem proteksi ini


ABSTRACT

Recently many companies or industries do not pay attention to lightning protection systems. The intensity of rainfall in Indonesia is quite high to make the possibility of lightning is also quite large. In this research discussed about the external lightning protection system located in Offtake Waru which is a gas receiving station. This protection system is needed because these locations are among the high-pressure gas pipeline which is explosive has a fairly wide area and many workers. The method used in this research is a checklist method that refers to PUIL 2000 and Permenaker No. 02 MEN 1989. Checklist method is used because it is easy and detailed so that can knows the real conditions that exist in the field. In the field project expected to provide information that the need for the application of an external lightning protection system is recognized. With the fulfillment of the provisions of the external lightning protection system at a work site employees can feel safe and makes the job becomes maximal. Maintenance and care must also be performed routinely in this protection system



KeywordsPetir; Proteksi eksternal; Offtake waru
 
Subject:  tegangan tinggi
Contributor
  1. Annas Singgih S., ST. MT.
Date Create: 29/09/2011
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-paper-64021130002223
Collection ID: 64021130002223
Call Number: 621.317 Wal a


Source
Presentation of Ship Electricity Engieering, 621.317 Wal a, 2013

Coverage
ITS Community

Rights
Copyright @2013 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-paper-27371-6408030009-Presentation.pdf - 1165 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 18.215.33.158
using CCBot/2.0 (https://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2020 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan