EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Institut Teknologi Sepuluh Nopember Surabaya


Kampus ITS Sukolilo - Surabaya 60111

Phone : 031-5921733 , 5923623
Fax : 031-5937774
E-mail : libits@its.ac.id
Website : http://library.its.ac.id

Support (Customer Service) :
timit_perpus@its.ac.id




Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Moh. Fandika Aqsa


Davi Wahyuni


Tondo Indra Nyata


Anis Wulandari


Ansi Aflacha




ITS » Paper and Presentation » Teknik Kes &Keselaman Kerja - D4
Posted by taujack@its.ac.id at 18/12/2013 11:06:03  •  1099 Views


EVALUASI SISTEM PROTEKSI PETIR DAN KESELAMATAN KERJA LISTRIK PADA PABRIK PERSONAL WASH PW PT. UNILEVER INDONESIA RUNGKUT SURABAYA

EVALUATION OF LIGHTNING PROTECTION SYSTEM AND ELECTRICAL SAFETY AT PERSONAL WASH PW FACTORY OF PT. UNILEVER INDONESIA RUNGKUT SURABAYA

Author :
HADI, MOHAMAD SAMSUL ( 6507040008 )




ABSTRAK

Pabrik Personal Wash PT.Unilever Surabaya merupakan pabrik yang memproduksi sabun mandi. Banyaknya permintaan pasar menyebabkan pabrik tersebut berencana untuk menambah area produksi baru yang terletak di gudang sebelah barat gudang RMS Room Material Score. Sistem proteksi petir pada area produksi yang baru belum terancang. Untuk keselamatan dan kesehatan kerja listrik khususnya pada panel belum mendapatkan maintenance yang baik. Penelitian ini akan membahas tentang evaluasi sistem proteksi petir berdasarkan Per. 02MEN1989 untuk mengetahui sistem proteksi petir yang dibutuhkan. Tindakan perbaikan yang direkomendasikan untuk area produksi baru berdasarkan Per. No. 02MEN1989 dan SNI IEC 623052009. Evaluasi keselamatan kerja listrik dengan menggunakan metode checklist dengan standart PUIL 2000. Berdasarkan hasil evaluasi ditemukan ketidaksesuaian antara lain air terminal hanya satu penghantar penurunan hanya satu panjang grounding yang digunakan melebihi standart. Berdasarkan hasil perhitungan menurut Per. 02MEN1989 area produksi baru membutuhkan sistem proteksi tambahan yaitu 2 air terminal 4 penghantar penurunan dan 2 buah elektroda batang. Berdasarkan SNI memerlukan proteksi tambahan yaitu 2 air terminal 2 penghantar penurunan dan merekomendasikan pondasi bangunan sebagai grounding. Untuk keselamatan kerja listrik perlu dilakukan perawatan yang baik terutama di dekat area limbah oli dan limbah pabrik.


ABSTRACT

Unilever factory Personal Wash Plant Surabaya Indonesian constitute factory that produce toilet soap. A lot of market order to cause that factory plans to add new production area that lies at western warehouse RMS warehouse Room Significant Score . Lightning protection system on production area a new one havent designed. For health and safety electric jobs particularly on pane has not gotten good maintenance. This research will discus about lightning protection system evaluation bases Per. 02 MEN 1989 to know needed lightning protection systems. Recommended remedial action for new production area bases Per. No. 02 MEN 1989 and SNI IEC 623052009. Evaluate occupational safety for electricity by use checklist method with standard of PUIL 2000. Based on evaluation result found some nonconformity for example just one air terminal so new production area was not protected as a whole just one downing conductor length of grounding which is utilized overshot standard. Based on result of arithmetic reffer to Per. 02 MEN 1989 new production areas need additional protection systems which is 2 air terminal 4 downing conductor and 2 bar electrodes. Based on the ISO require additional protection which is 2 air terminal 2 downing conductor and recommends building foundations as a grounding. For occupational safety of electricity needs to be done by good care especially at elbow oils waste area and factory waste.



KeywordsSistem Proteksi Petir; Keselamatan Kerja Listrik; Metode Checklist
 
Subject:  Keselamatan Kerja
Contributor
  1. Annas Singgih S., ST. MT.
  2. Wibowo Arnin P., ST. M.Kom
Date Create: 18/12/2013
Type: Text
Format: PDF
Language: Indonesian
Identifier: ITS-paper-65011300003084
Collection ID: 65011300003084


Source
Undergraduate Theses of healt and safety engineering 620.86 Had e, 2013

Coverage
ITS Community

Rights
Copyright @2013 by ITS Library. This publication is protected by copyright and per obtained from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form or by any means, electronic, mechanical, photocopying, reco For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-paper-28381-6507040008-Presentation.pdf - 839 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.80.26.116
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2017 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan