Posted by sarwono@its.ac.id at 08/03/2010 14:31:44  •  2920 Views


DESAIN INSTALASI PEMADAM KEBAKARAN PADA STADION SURABAYA SPORT CENTER KECAMATAN BENOWO SURABAYA

DESIGN OF INSTALLATION FIRE EXTINGUISHER AT STADIUM SURABAYA SPORT CENTER SUBDISTRICT BENOWO SURABAYA

Author :
Mustafa, Arief Randi ( 3105040754 )




ABSTRAK

Kebakaran adalah suatu reaksi kimia yang berlangsung cepat dan memancarkan panas serta sinar. Reaksi yang timbul merupakan reaksi oksidasi. Terjadinya suatu kebakaran disebabkan oleh 3 unsur yaitu bahan bakar oksigen dan panas. Oleh karena itu usaha pencegahan sangat diperlukan untuk menghambat terjadinya kebakaran yang meluas. Pencegahan kebakaran adalah usaha mewaspadai akan faktor-faktor yang menjadi sebab terjadinya kebakaran dan mengambil langkah-langkah untuk mencegah kemungkinan tersebut menjadi kenyataan. Pencegahan kebakaran membutuhkan suatu program pendidikan dan pengawasan suatu rencana pemeliharaan yang cermat dan teratur atas bangunan dan kelengkapannya pemeriksaan penyediaan dan penempatan yang baik dari peralatan pemadam kebakaran termasuk memeliharanya baik segi siap pakai maupun dari segi mudah dicapainya. Peralatan pemadam kebakaran yang merupakan bagian pokok yang sangat penting dalam penanggulangan kebakaran yang harusnya mendapat perawatan yang baik pula agar jika sewaktu-waktu terjadi kebakaran hidran sprinkler dan alat pemadam api ringan APAR dapat digunakan dengan baik dan tanpa hambatan.


ABSTRACT

Fire is a chemical reaction that takes place rapidly and emits heat and rays. Reaction that occurs are oxidation reactions. The occurrence of a fire caused by 3 elements which are fuel oxygen and heat. Therefore prevention efforts are needed to prevent the occurrence of widespread fires. Fire prevention is an effort to cautious factors that causes the occurrence of a fire and takes steps to prevent the possibility becomes reality. Fire prevention requires an education program and supervision careful and regular maintenance planning of building and its completeness inspection provision and lacement of the fire rescue equipment including its maintenance the fire department terms of both ready and easily accessible. Fire equipment is the very important principal part in andling a fire that should get good maintenance that if at any time a fire occurs hydrant sprinkler and light fire extinguisher 9 can be used both with and without obstacles.



KeywordsInstalasi Pemadam Kebakaran; Hidran; Sprinkler; APAR (Alat Pemadam Api Ringan)
 
Subject:  Pemadam kebakaran
Contributor
  1. Ir.Akh.Yusuf Zuhdy, PG.Dipl.Plg, MRE
Date Create: 08/03/2010
Type: Text
Format: pdf
Language: Indonesian
Identifier: ITS-Undergraduate-3100010037626
Collection ID: 3100010037626
Call Number: RSS 628.925 2 Mus d


Source
Undergraduate theses, Civil Engineering , RSS 628.925 2 Mus d, 2009

Coverage
ITS Community Only

Rights
Copyright @2009 by ITS Library. This publication is protected by copyright and permission should be obtained from the ITS Library prior to any prohibited reproduction, storage in a retrievel system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permission(s), write to ITS Library




[ Download - Open Access ]

  1.  ITS-Undergraduate-8723-3105040754-Abstract_in.pdf - 10 KB
  2.  ITS-Undergraduate-8723-3105040754-Abstract_en.pdf - 10 KB
  3.  ITS-Undergraduate-8723-3105040754-Conclusion.PDF - 21 KB




 Similar Document...




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely

Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

POLLING

Bagaimana pendapat Anda tentang layanan repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan





You are connected from 54.161.3.108
using CCBot/2.0 (http://commoncrawl.org/faq/)



Copyright © ITS Library 2006 - 2016 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan